iFluor™ 350-streptavidin conjugate

! Interactive Product Finder: This product has alternative forms and/or upgrades. View now


Image Viewer
<p>HeLa cells were incubated with mouse anti-tubulin and biotin goat anti-mouse IgG followed by AAT’s iFluor™ 350-streptavidin conjugate.</p>
Roll over image to zoom in
Loading...
 
Unit Size: Cat No: Price (USD): Qty:
16950 $75


Export item/cart as Excel file

Send item/cart as email
EXPORT TO EXCEL X

Export:
EXPORT TO EMAIL X
Important: We request your email address to ensure that the recipient(s) knows you intended for them to see the email, and that it is not junk mail.
Export:
Your Name*:
Your Email*:
Recipient Email*:
Your Personal Message:
Additional Ordering Information
Telephone: 1-800-990-8053
Fax: 1-408-733-1304
Email: sales@aatbio.com
International: See distributors





Overview

Ex/Em (nm)344/448
SolventWater
Storage Freeze (<-15 °C)
Minimize light exposure
Category Immunology
Streptavidin Conjugates
Related
AAT Bioquest's iFluor™ dyes are optimized for labeling proteins, in particular, antibodies. These dyes are bright, photostable and have minimal quenching on proteins. They can be well excited by the major laser lines of fluorescence instruments (e.g., 350, 405, 488, 555 and 633 nm). Streptavidin conjugates are widely used together with a conjugate of biotin for specific detection of a variety of proteins, protein motifs, nucleic acids and other molecules since streptavidin has a very high binding affinity for biotin. A variety of the complementary biotinylated reagents are available from numerous commercial vendors.This iFluor™ 350-streptavidin conjugate comprises streptavidin (as the biotin-binding protein) with iFluor™ 350 covalently attached (as the fluorescent label). It is commonly used as a second step reagent for indirect immunofluorescent staining, when used in conjunction with biotinylated primary antibodies. iFluor™ 350-streptavidin conjugate has fluorescence excitation and emission maxima of ~345 nm and ~442 nm respectively. These spectral characteristics make it an excellent alternative to Alexa Fluor® 350-streptavidin conjugate (Alexa Fluor® is the trademark of Invitrogen). It is a very valuable tool for biotin-streptavidin-based biological assays and tests.




Spectrum Advanced Spectrum Viewer

Sorry, your browser does not support inline SVG. Relative Intensity (%) 100 80 60 40 20 0 Sorry, your browser does not support inline SVG.
Sorry, your browser does not support inline SVG. Sorry, your browser does not support inline SVG.
Move mouse over grid to display wavelength & intensity values.

300
400
500
600
700
800
900
Wavelength (nm)





Interactive Product Finder

Related products
Product nameCurrent ProductRelated Product
HRP-streptavidin conjugate
iFluor™ 350
HRP
trFluor™ Eu-streptavidin conjugate
iFluor™ 350
trFluor™ Eu
Cy7®-streptavidin conjugate
iFluor™ 350
Cy7®
See More (37)
FITC-streptavidin conjugate
iFluor™ 350
FITC
iFluor™ 647-streptavidin conjugate
350
647
Cy5®-streptavidin conjugate
iFluor™ 350
Cy5®
iFluor™ 405-streptavidin conjugate
350
405
Cy3®-streptavidin conjugate
iFluor™ 350
Cy3®
APC-streptavidin conjugate
iFluor™ 350
APC
RPE-streptavidin conjugate
iFluor™ 350
RPE
iFluor™ 555-streptavidin conjugate
350
555
trFluor™ Tb-streptavidin conjugate
iFluor™ 350
trFluor™ Tb
iFluor™ 488-streptavidin conjugate
350
488
iFluor™ 594-streptavidin conjugate
350
594
RPE-iFluor™ 647-streptavidin conjugate
350
RPE
647
iFluor™ 750-streptavidin conjugate
350
750
iFluor™ 568-streptavidin conjugate
350
568
iFluor™ 700-streptavidin conjugate
350
700
APC-iFluor™ 750-streptavidin conjugate
350
APC
750
iFluor™ 633-streptavidin conjugate
350
633
PerCP-streptavidin conjugate
iFluor™ 350
PerCP
Texas Red®-streptavidin conjugate
iFluor™ 350
Texas Red®
RPE-iFluor™ 750-streptavidin conjugate
350
RPE
750
mFluor™ Red 780-streptavidin conjugate
iFluor™ 350
mFluor™ Red 780
mFluor™ Violet 450-streptavidin conjugate
iFluor™ 350
mFluor™ Violet 450
iFluor™ 546-streptavidin conjugate
350
546
iFluor™ 680-streptavidin conjugate
350
680
mFluor™ Blue 570-streptavidin conjugate
iFluor™ 350
mFluor™ Blue 570
mFluor™ Red 700-streptavidin conjugate
iFluor™ 350
mFluor™ Red 700
mFluor™ Violet 540-streptavidin conjugate
iFluor™ 350
mFluor™ Violet 540
RPE-Cy7-streptavidin conjugate
iFluor™ 350
RPE Cy7
mFluor™ Yellow 630-streptavidin conjugate
iFluor™ 350
mFluor™ Yellow 630
mFluor™ Green 620-streptavidin conjugate
iFluor™ 350
mFluor™ Green 620
iFluor™ 514-streptavidin conjugate
350
514
mFluor™ Violet 510-streptavidin conjugate
iFluor™ 350
mFluor™ Violet 510
iFluor™ 532-streptavidin conjugate
350
532


Similar products




References

Overexpression of MACC1 and the association with hepatocyte growth factor/c-Met in epithelial ovarian cancer
Authors: Hongyu Li, Hui Zhang, Shujun Zhao, Yun Shi, Junge Yao, Yanyan Zhang, Huanhuan Guo, Xingsuo Liu
Journal: Oncology letters (2015): 1989--1996






Resources
 
Safety Data Sheet (SDS)


Documents
1. Fluorescent Labeling Probes & Kits

Certificate of Analysis