logo
AAT Bioquest

Cell Meter™ APC-Annexin V Binding Apoptosis Assay Kit *Optimized for Flow Cytometry*

The detection of binding activity of APC-Annexin V to phosphatidylserine in Jurkat cells with Cell Meter™ APC-Annexin V Binding Apoptosis Assay Kit. Jurkat cells were treated without (Blue) or with 1 µM staurosporine (Red) in a 37 °C, 5% CO2 incubator for ~4 hours, and then dye loaded with APC-Annexin V for 30 minutes. The fluorescence intensity of APC-Annexin V was measured with a FACSCalibur (Becton Dickinson) flow cytometer using the FL4 channel.
The detection of binding activity of APC-Annexin V to phosphatidylserine in Jurkat cells with Cell Meter™ APC-Annexin V Binding Apoptosis Assay Kit. Jurkat cells were treated without (Blue) or with 1 µM staurosporine (Red) in a 37 °C, 5% CO2 incubator for ~4 hours, and then dye loaded with APC-Annexin V for 30 minutes. The fluorescence intensity of APC-Annexin V was measured with a FACSCalibur (Becton Dickinson) flow cytometer using the FL4 channel.
The detection of binding activity of APC-Annexin V to phosphatidylserine in Jurkat cells with Cell Meter™ APC-Annexin V Binding Apoptosis Assay Kit. Jurkat cells were treated without (Blue) or with 1 µM staurosporine (Red) in a 37 °C, 5% CO2 incubator for ~4 hours, and then dye loaded with APC-Annexin V for 30 minutes. The fluorescence intensity of APC-Annexin V was measured with a FACSCalibur (Becton Dickinson) flow cytometer using the FL4 channel.
Ordering information
Price
Catalog Number
Unit Size
Quantity
Add to cart
Additional ordering information
Telephone1-800-990-8053
Fax1-800-609-2943
Emailsales@aatbio.com
InternationalSee distributors
Bulk requestInquire
Custom sizeInquire
ShippingStandard overnight for United States, inquire for international
Request quotation
Spectral properties
Correction Factor (280 nm)0.195
Extinction coefficient (cm -1 M -1)730000
Excitation (nm)651
Emission (nm)660
Storage, safety and handling
H-phraseH303, H313, H333
Hazard symbolXN
Intended useResearch Use Only (RUO)
R-phraseR20, R21, R22
UNSPSC12352200
Related products
Cell Meter™ Intracellular Fluorimetric Hydrogen Peroxide Assay Kit *Green Fluorescence*
Cell Meter™ Intracellular Fluorimetric Hydrogen Peroxide Assay Kit *Blue Fluorescence*
Cell Meter™ Intracellular Fluorimetric Hydrogen Peroxide Assay Kit *Blue Fluorescence Optimized for Flow Cytometry*
Cell Meter™ Intracellular Fluorimetric Hydrogen Peroxide Assay Kit *Green Fluorescence Optimized for Flow Cytometry*
Cell Meter™ Mitochondrial Hydroxyl Radical Detection Kit *Red Fluorescence*
Cell Meter™ Fluorimetric Mitochondrial Superoxide Activity Assay Kit *Green Fluorescence*
Cell Meter™ Fluorimetric Intracellular Peroxynitrite Assay Kit *Green Fluorescence*
Cell Meter™ Fluorimetric Intracellular Peroxynitrite Assay Kit *Optimized for Flow Cytometry*
Cell Meter™ Fluorimetric Intracellular Nitric Oxide (NO) Activity Assay Kit *Orange Fluorescence Optimized for Microplate Reader*
Cell Meter™ Fluorimetric Intracellular Nitric Oxide (NO) Activity Assay Kit *Orange Fluorescence Optimized for Flow Cytometry*
Cell Meter™ Fluorimetric Intracellular Nitric Oxide (NO) Activity Assay Kit *Red Fluorescence Optimized for Flow Cytometry*
Cell Meter™ Live Cell Caspase 3/7 Binding Assay Kit *Green Fluorescence*
Cell Meter™ Live Cell Caspase 3/7 Binding Assay Kit *Red Fluorescence*
Cell Meter™ Live Cell Caspase 1 Binding Assay Kit *Green Fluorescence*
Cell Meter™ Live Cell Caspase 2 Binding Assay Kit *Green Fluorescence*
Cell Meter™ Live Cell Caspase 6 Binding Assay Kit *Green Fluorescence*
Cell Meter™ Live Cell Caspase 8 Binding Assay Kit *Green Fluorescence*
Cell Meter™ Live Cell Caspase 9 Binding Assay Kit *Green Fluorescence*
Cell Meter™ Live Cell Caspase 10 Binding Assay Kit *Green Fluorescence*
Cell Meter™ Live Cell Caspase 13 Binding Assay Kit *Green Fluorescence*
Cell Meter™ No-Wash Live Cell Caspase 3/7 Activity Assay Kit *Blue Fluorescence*
Cell Meter™ No-Wash Live Cell Caspase 3/7 Activity Assay Kit *Red Fluorescence*
Cell Meter™ Fluorimetric Intracellular pH Assay Kit
Cell Meter™ Fluorimetric Cell Cytotoxicity Assay Kit
Cell Meter™ Cell Viability Assay Kit *Red Fluorescence*
Cell Meter™ Cell Viability Assay Kit *Blue Fluorescence with 405 nm Excitation*
Cell Meter™ Cell Viability Assay Kit *Blue Fluorescence*
Cell Meter™ Cell Viability Assay Kit *Green Fluorescence*
Cell Meter™ Cell Viability Assay Kit *NIR Fluorescence Optimized for Fluorescence Microplate Reader*
Cell Meter™ Phosphatidylserine Apoptosis Assay Kit *Blue Fluorescence Optimized for Microplate Readers*
Cell Meter™ Phosphatidylserine Apoptosis Assay Kit *Green Fluorescence Optimized for Microplate Readers*
Cell Meter™ Phosphatidylserine Apoptosis Assay Kit *Red Fluorescence Optimized for Microplate Readers*
Cell Meter™ Phosphatidylserine Apoptosis Assay Kit *Deep Red Fluorescence Optimized for Microplate Readers*
Cell Meter™ Phosphatidylserine Apoptosis Assay Kit *Orange Fluorescence Optimized for Microplate Readers*
Cell Meter™ Caspase 3/7 Activity Apoptosis Assay Kit *Blue Fluorescence*
Cell Meter™ Caspase 3/7 Activity Apoptosis Assay Kit *Green Fluorescence*
Cell Meter™ Caspase 3/7 Activity Apoptosis Assay Kit *Red Fluorescence*
Cell Meter™ Caspase 8 Activity Apoptosis Assay Kit *Green Fluorescence*
Cell Meter™ Caspase 9 Activity Apoptosis Assay Kit *Green Fluorescence*
Cell Meter™ JC-10 Mitochondrion Membrane Potential Assay Kit *Optimized for Microplate Assays*
Cell Meter™ JC-10 Mitochondrion Membrane Potential Assay Kit *Optimized for Flow Cytometry Assays*
Cell Meter™ NIR Mitochondrion Membrane Potential Assay Kit *Optimized for Flow Cytometry*
Cell Meter™ NIR Mitochondrion Membrane Potential Assay Kit *Optimized for Microplate Reader*
Cell Meter™ Mitochondrion Membrane Potential Assay Kit *Orange Fluorescence Optimized for Flow Cytometry*
Cell Meter™ Mitochondrion Membrane Potential Assay Kit *Orange Fluorescence Optimized for Microplate Reader*
Cell Meter™ Intracellular GSH Assay Kit *Optimized for Flow Cytometry*
Cell Meter™ Nuclear Apoptosis Assay Kit *Green Fluorescence Optimized for Flow Cytometry*
Cell Meter™ Caspase 8 Activity Apoptosis Assay Kit *Blue Fluorescence*
Cell Meter™ Caspase 9 Activity Apoptosis Assay Kit *Blue Fluorescence*
Cell Meter™ Caspase 8 Activity Apoptosis Assay Kit *Red Fluorescence*
Cell Meter™ Caspase 9 Activity Apoptosis Assay Kit *Red Fluorescence*
Cell Meter™ Multiplexing Caspase 3/7, 8 and 9 Activity Assay Kit *Triple Fluorescence Colors*
Cell Meter™ Generic Fluorimetric Caspase Activity Assay Kit *Green Fluorescence Optimized for Flow Cytometry*
Cell Meter™ Generic Fluorimetric Caspase Binding Assay Kit *Red Fluorescence Optimized for Flow Cytometry*
Cell Meter™ Caspase 3/7 Activity Apoptosis Assay Kit *Green Fluorescence Optimized for Flow Cytometry*
Cell Meter™ Annexin V Binding Apoptosis Assay Kit *Green Fluorescence Optimized for Flow Cytometry*
Cell Meter™ Annexin V Binding Apoptosis Assay Kit *Orange Fluorescence Optimized for Flow Cytometry*
Cell Meter™ Annexin V Binding Apoptosis Assay Kit *Red Fluorescence Optimized for Flow Cytometry*
Cell Meter™ Annexin V Binding Apoptosis Assay Kit *Deep Red Fluorescence Optimized for Flow Cytometry*
Cell Meter™ Annexin V Binding Apoptosis Assay Kit *Blue Fluorescence Excited at 405 nm*
Cell Meter™ Annexin V Binding Apoptosis Assay Kit *Green Fluorescence Excited at 405 nm*
Cell Meter™ Annexin V Binding Apoptosis Assay Kit *Orange Fluorescence Excited at 405 nm*
Cell Meter™ Phosphatidylserine Apoptosis Assay Kit *Green Fluorescence Optimized for Flow Cytometry*
Cell Meter™ Phosphatidylserine Apoptosis Assay Kit *Deep Red Fluorescence Optimized for Flow Cytometry*
Cell Meter™ Phosphatidylserine Apoptosis Assay Kit *Blue Fluorescence Excited at 405 nm*
Cell Meter™ Phosphatidylserine Apoptosis Assay Kit *Green Fluorescence Excited at 405 nm*
Cell Meter™ Apoptotic and Necrotic Multiplexing Detection Kit I *Triple Fluorescence Colors*
Cell Meter™ Fluorimetric Live Cell Cycle Assay Kit *Green Fluorescence Optimized for Flow Cytometry*
Cell Meter™ Fluorimetric Fixed Cell Cycle Assay Kit *Red Fluorescence Optimized for Flow Cytometry*
Cell Meter™ Apoptotic and Necrotic Multiplexing Detection Kit II *Triple Fluorescence Colors*
Cell Meter™ Live Cell TUNEL Apoptosis Assay Kit *Red Fluorescence*
Cell Meter™ Fluorimetric Live Cell Cycle Assay Kit *Optimized for 405 nm Violet Laser Excitation*
Cell Meter™ Live Cell Caspase 3/7 and Phosphatidylserine Detection Kit *Triple Fluorescence Colors*
Cell Meter™ Fluorimetric Intracellular Total ROS Activity Assay Kit*Green Fluorescence*
Cell Meter™ Fluorimetric Intracellular Total ROS Activity Assay Kit*Red Fluorescence*
Cell Meter™ Fluorimetric Intracellular Total ROS Activity Assay Kit*Orange Fluorescence*
Cell Meter™ Fluorimetric Intracellular Total ROS Activity Assay Kit*Deep Red Fluorescence*
Cell Meter™ Fluorimetric Intracellular Total ROS Activity Assay Kit*Optimized for Flow Cytometry*
Cell Meter™ Fluorimetric Mitochondrial Superoxide Activity Assay Kit*Optimized for Flow Cytometry*
Cell Meter™ Fluorimetric Mitochondrial Superoxide Activity Assay Kit*Optimized for Microplate Reader*
Cell Meter™ Autophagy Assay Kit *Blue Fluorescence*
Cell Meter™ Autophagy Fluorescence Imaging Kit
Cell Meter™ Autophagy Assay Kit *Green Fluorescence*
Cell Meter™ Fluorimetric Intracellular Nitric Oxide (NO) Activity Assay Kit *NIR Fluorescence Optimized for Microplate Reader*
Cell Meter™ Fluorimetric Intracellular Nitric Oxide (NO) Activity Assay Kit *NIR Fluorescence Optimized for Flow Cytometry*
Cell Meter™ Colorimetric WST-8 Cell Quantification Kit
Cell Meter™ Multiplexing Live, Apoptotic and Necrotic Cell Detection Kit III *Triple Fluorescence Colors*
Cell Meter™ 2-NBDG Glucose Uptake Assay Kit
Cell Meter™ Intracellular NADH/NADPH Fluorescence Imaging Kit *Red Fluorescence*
Cell Meter™ Intracellular NADH/NADPH Flow Cytometric Analysis Kit *Red Fluorescence*
Cell Meter™ Live Cell TUNEL Apoptosis Assay Kit *Green Fluorescence*
Cell Meter™ No Wash and Probenecid-Free Endpoint Calcium Assay Kit *Optimized for microplate reader*
Cell Meter™ Mitochondrion Membrane Potential Assay Kit *Red Fluorescence Optimized for Flow Cytometry*
Cell Meter™ Mitochondrion Membrane Potential Assay Kit *Red Fluorescence Optimized for Microplate Reader*
Cell Meter™ Intracellular Colorimetric Lipid Peroxidation (MDA) Assay Kit
Cell Meter™ Flow Cytometric Calcium Assay Kit
Cell Meter™ Fluorimetric Live Cell Cycle Assay Kit *Red Fluorescence Optimized for Flow Cytometry*
Cell Meter™ Fluorimetric Cellular Lipid Peroxidation Assay Kit
Cell Meter™ Intracellular NADH/NADPH Fluorescence Imaging Kit *Deep Red Fluorescence*
Cell Meter™ Intracellular NADH/NADPH Flow Cytometric Analysis Kit *Deep Red Fluorescence*
Cell Meter™ Intracellular GSH Assay Kit *Optimized for Flow Cytometry with 405 nm excitation*
Cell Meter™ Mitochondrial Autophagy Imaging Kit *Red Fluorescence*
Cell Meter™ BX520 fixable viability dye
Cell Meter™ BX590 fixable viability dye
Cell Meter™ BX650 fixable viability dye
Cell Meter™ IX830 fixable viability dye
Cell Meter™ RX660 fixable viability dye
Cell Meter™ RX700 fixable viability dye
Cell Meter™ RX780 fixable viability dye
Cell Meter™ VX450 fixable viability dye
Cell Meter™ VX500 fixable viability dye
Cell Meter™ Live Cell Caspase 8 Binding Assay Kit *Red Fluorescence*
Cell Meter™ Fixed Cell and Tissue TUNEL Apoptosis Assay Kit *Green Fluorescence*
Cell Meter™ Fixed Cell and Tissue TUNEL Apoptosis Assay Kit *Red Fluorescence*
Cell Meter™ Fluorimetric Cellular Voltage Assay Kit
Cell Meter™ Cell Adhesion Assay Kit
Cell Meter™ Fixed Cell and Tissue TUNEL Apoptosis Assay Kit *Deep Red Fluorescence*
Cell Meter™ Fixed Cell and Tissue TUNEL Apoptosis Assay Kit *Blue Fluorescence*
Cell Meter™ Fluorescence Gap Junction Tracing Kit
Cell Meter™ Colorimetric MTT Cell Proliferation Kit
Cell Meter™ Live Cell Caspase 3/7 Imaging Kit *Green Fluorescence*
Cell Meter™ Beta-Arrestin Translocation GPCR Signaling Kit
Cell Meter™ Live Cell ATP Assay Kit
Cell Meter™ Colorimetric Cell Cytotoxicity Assay Kit
Cell Meter™ Fluorimetric Phagocytosis Assay Kit *Red Fluorescence*
Cell Meter™ Cellular Senescence Activity Assay Kit *Green Fluorescence*
Cell Meter™ Cellular Senescence Activity Assay Kit *Red Fluorescence*
Cell Meter™ Cell Proliferation Assay Kit
Cell Meter™ Glucose Uptake Imaging Kit *Red Fluorescence*
Cell Meter™ Colorimetric MTS Cell Proliferation Kit
Show More (120)

OverviewpdfSDSpdfProtocol


Correction Factor (280 nm)
0.195
Extinction coefficient (cm -1 M -1)
730000
Excitation (nm)
651
Emission (nm)
660
Annexin V may be conjugated to fluorochromes including APC. This format retains its high affinity for phosphatidylserine (PS) and thus serves as a sensitive probe for flow cytometric analysis of cells that are undergoing apoptosis. Since externalization of PS occurs in the earlier stages of apoptosis, APC Annexin V staining can identify apoptosis at an earlier stage than assays based on nuclear changes such as DNA fragmentation. APC Annexin V staining precedes the loss of membrane integrity which accompanies the latest stages of cell death resulting from either apoptotic or necrotic processes. Therefore, staining with APC Annexin V is typically used in conjunction with a vital dye such as propidium iodide (PI) or 7-Amino-Actinomycin (7-AAD) to allow the investigator to identify early apoptotic cells.

Platform


Flow cytometer

Excitation640 nm laser
Emission660/20 nm filter
Instrument specification(s)APC channel

Components


Example protocol


AT A GLANCE

Protocol summary

  1. Prepare cells with test compounds (200 µL/sample) 
  2. Add APC-Annexin V assay solution
  3. Incubate at room temperature for 20 - 60 minutes
  4. Analyze cells using flow cytometer with 660/20 nm filter (APC channel)

Important notes
Thaw 100X Propidium Iodide (Component C) at room temperature before starting the experiment.

PREPARATION OF STOCK SOLUTION

Unless otherwise noted, all unused stock solutions should be divided into single-use aliquots and stored at -20 °C after preparation. Avoid repeated freeze-thaw cycles.

1. APC-Annexin V stock solution (100X):
Add 200 µL PBS with 0.2% BSA into the vial of APC-Annexin V conjugate (Component A) and mix well to make 100X APC-Annexin V stock solution. Note: Store the reconstituted 100X APC-Annexin V stock solution at 4 oC. Do Not Freeze.

For guidelines on cell sample preparation, please visit
https://www.aatbio.com/resources/guides/cell-sample-preparation.html

SAMPLE EXPERIMENTAL PROTOCOL

  1. Treat cells with test compounds for a desired period of time (4-6 hours for Jurkat cells treated with staurosporine) to induce apoptosis. Note: Annexin V flow cytometric analysis on adherent cells is not routinely tested since specific membrane damage may occur during cell detachment or harvesting. However, methods for utilizing Annexin V for flow cytometry on adherent cell types have been previously reported by Casiola-Rosen et al. and van Engelend et al.
     
  2. Centrifuge the cells to get 1-5 × 105 cells/tube.

  3. Resuspend cells in 200 µL of Assay Buffer (Component B).

  4. Add 2 µL of 100X APC-Annexin V stock solution into the cells.

  5. Optional: Add 2 µL of 100X Propidium Iodide (Component C) into the cells for necrosis cells.

  6. Incubate at room temperature for 20 to 60 minutes, protected from light.

  7. Optional: Add 200 to 300 µL of Assay Buffer (Component B) to increase volume before analyzing the cells with a flow cytometer.

  8. Monitor the fluorescence intensity of APC-Annexin V using a flow cytometer with 660/20 nm filter (APC channel). Measure the cell viability using 610/20 nm filter (PE-Texas Red channel) when propidium iodide is added into the cells.

Spectrum


Open in Advanced Spectrum Viewer
spectrum

Spectral properties

Correction Factor (280 nm)0.195
Extinction coefficient (cm -1 M -1)730000
Excitation (nm)651
Emission (nm)660

Product Family


NameExcitation (nm)Emission (nm)Extinction coefficient (cm -1 M -1)Quantum yieldCorrection Factor (280 nm)
Cell Meter™ PE-Annexin V Binding Apoptosis Assay Kit *Optimized for Flow Cytometry*56557419600000.820.175
Cell Meter™ FITC-Annexin V Binding Apoptosis Assay Kit *Optimized for Flow Cytometry*491516730000.920.35

Images


Citations


View all 10 citations: Citation Explorer
Upregulation of LPGAT1 Enhances Lung Adenocarcinoma Proliferation
Authors: Gong, Huiyuan and Ma, Chao and Li, Xiaojun and Zhang, Xueying and Zhang, Linxiang and Chen, Pengfei and Wang, Wei and Hu, Yannan and Huang, Ting and Wu, Nan and others,
Journal: Frontiers in Bioscience-Landmark (2023): 89
BRAF D594A mutation defines a unique biological and immuno-modulatory subgroup associated with functional CD8+ T cell infiltration in colorectal cancer
Authors: Li, Wenjing and Zhao, Chenyi and Li, Wenhui and Gong, Yang and Ma, Kaili and Lu, Yujie and Liu, Xiaowei and Zhang, Lianjun and Guo, Feng
Journal: (2023)
Th22/IL-22 mediates the progression of HBV-related hepatocellular carcinoma via STAT3
Authors: Zhang, Jia and Liu, Zhou and Liu, Lingpeng and Huang, Mingwen and Huang, Yong
Journal: Cytotechnology (2022): 203--216
Effects of Y-27632 on the osteogenic and adipogenic potential of human dental pulp stem cells in vitro
Authors: Xie, Zhiwei and Xu, Qiuping and Sun, Lu and Li, Ruijing and Shi, Jizhou and Yang, Qian and Zong, Min and Qin, Jianyong
Journal: Human \& Experimental Toxicology (2022): 09603271221089003
Knockdown of CENPK inhibits cell growth and facilitates apoptosis via PTEN-PI3K-AKT signalling pathway in gastric cancer
Authors: Wu, Shusheng and Cao, Lulu and Ke, Lihong and Yan, Ying and Luo, Huiqin and Hu, Xiaoxiu and Niu, Jiayu and Li, Huimin and Xu, Huijun and Chen, Wenju and others,
Journal: Journal of Cellular and Molecular Medicine (2021): 8890--8903
FIGNL1 promotes non-small cell lung cancer cell proliferation
Authors: Li, Miao and Rui, Yan and Peng, Wenjia and Hu, Junfeng and Jiang, Anbang and Yang, Zeyu and Huang, Linian
Journal: International journal of oncology (2020): 83--99
Babao Dan induces gastric cancer cell apoptosis via regulating MAPK and NF-$\kappa$B signaling pathways
Authors: Shang, Haixia and Cao, Zhiyun and Zhao, Jinyan and Guan, Jianhua and Liu, Jianxin and Peng, Jun and Chen, Youqin and Joseph Sferra, Thomas and Sankararaman, Senthilkumar and Lin, Jiumao
Journal: Journal of International Medical Research (2019): 5106--5119
CHIP functions as an oncogene by promoting colorectal cancer metastasis via activation of MAPK and AKT signaling and suppression of E-cadherin
Authors: Xu, Jingjing and Zhou, Jun and Dai, Hanjue and Liu, Fei and Li, Wenjing and Wang, Wenjuan and Guo, Feng
Journal: Journal of Translational Medicine (2018): 169
Ubiquitin ligase CHIP functions as an oncogene and activates the AKT signaling pathway in prostate cancer
Authors: Cheng, Li and Zang, Jin and Dai, Han-Jue and Li, Feng and Guo, Feng
Journal: International journal of oncology (2018)
ALDH1 Bio-activates Nifuroxazide to Eradicate ALDHHigh Melanoma-Initiating Cells
Authors: Sarvi, Sana and Crispin, Richard and Lu, Yuting and Zeng, Lifan and Hurley, Thomas D and Houston, Douglas R and von Kriegsheim, Alex and Chen, Che-Hong and Mochly-Rosen, Daria and Ranzani, Marco and others, undefined
Journal: Cell Chemical Biology (2018)

References


View all 135 references: Citation Explorer
Suicidal membrane repair regulates phosphatidylserine externalization during apoptosis
Authors: Mirnikjoo B, Balasubramanian K, Schroit AJ.
Journal: J Biol Chem (2009): 22512
Peptidic targeting of phosphatidylserine for the MRI detection of apoptosis in atherosclerotic plaques
Authors: Burtea C, Laurent S, Lancelot E, Ballet S, Murariu O, Rousseaux O, Port M, V and er Elst L, Corot C, Muller RN.
Journal: Mol Pharm (2009): 1903
Apoptosis of human Burkitt's lymphoma cells induced by 2-N,N-diethylaminocarbonyloxymethyl-1-diphenylmethyl-4-(3,4,5-trimethoxybe nzoyl) piperazine hydrochloride (PMS-1077)
Authors: Wang WD, Xu XM, Chen Y, Jiang P, Dong CZ, Wang Q.
Journal: Arch Pharm Res (2009): 1727
Induction of apoptosis in sonoporation and ultrasonic gene transfer
Authors: Miller DL, Dou C.
Journal: Ultrasound Med Biol (2009): 144
Detection of apoptosis based on the interaction between annexin V and phosphatidylserine
Authors: Liu T, Zhu W, Yang X, Chen L, Yang R, Hua Z, Li G.
Journal: Anal Chem (2009): 2410
Evaluation of cell surface expression of phosphatidylserine in ovarian carcinoma effusions using the annexin-V/7-AAD assay: clinical relevance and comparison with other apoptosis parameters
Authors: Dong HP, Holth A, Kleinberg L, Ruud MG, Elstr and MB, Trope CG, Davidson B, Risberg B.
Journal: Am J Clin Pathol (2009): 756
Gold fluorescent annexin A5 as a novel apoptosis detection tool
Authors: Kurschus FC, Pal PP, Baumler P, Jenne DE, Wiltschi B, Budisa N.
Journal: Cytometry A (2009): 626
Mobilization of lysosomal calcium regulates the externalization of phosphatidylserine during apoptosis
Authors: Mirnikjoo B, Balasubramanian K, Schroit AJ.
Journal: J Biol Chem (2009): 6918
Eurycomanone induce apoptosis in HepG2 cells via up-regulation of p53
Authors: Zakaria Y, Rahmat A, Pihie AH, Abdullah NR, Houghton PJ.
Journal: Cancer Cell Int (2009): 16
Dynamic analysis of apoptosis using cyanine SYTO probes: from classical to microfluidic cytometry
Authors: Wlodkowic D, Skommer J, Faley S, Darzynkiewicz Z, Cooper JM.
Journal: Exp Cell Res (2009): 1706