logo
AAT Bioquest

ReadiLink™ Protein Biotinylation Kit

Product Image
Product Image
Gallery Image 1
Ordering information
Price
Catalog Number
Unit Size
Quantity
Add to cart
Additional ordering information
Telephone1-800-990-8053
Fax1-800-609-2943
Emailsales@aatbio.com
InternationalSee distributors
Bulk requestInquire
Custom sizeInquire
ShippingStandard overnight for United States, inquire for international
Request quotation
Storage, safety and handling
Certificate of OriginDownload PDF
H-phraseH303, H313, H333
Hazard symbolXN
Intended useResearch Use Only (RUO)
R-phraseR20, R21, R22
UNSPSC12352200
Related products
ReadiLink™ Rapid mFluor™ Violet 450 Antibody Labeling Kit *Microscale Optimized for Labeling 50 μg Antibody Per Reaction*
ReadiLink™ Rapid mFluor™ Violet 420 Antibody Labeling Kit *Microscale Optimized for Labeling 50 μg Antibody Per Reaction*
ReadiLink™ Rapid mFluor™ Violet 510 Antibody Labeling Kit *Microscale Optimized for Labeling 50 μg Antibody Per Reaction*
ReadiLink™ Rapid mFluor™ Violet 540 Antibody Labeling Kit *Microscale Optimized for Labeling 50 μg Antibody Per Reaction*
ReadiLink™ Rapid mFluor™ Blue 570 Antibody Labeling Kit *Microscale Optimized for Labeling 50 μg Antibody Per Reaction*
ReadiLink™ Rapid mFluor™ Green 620 Antibody Labeling Kit *Microscale Optimized for Labeling 50 μg Antibody Per Reaction*
ReadiLink™ Rapid mFluor™ Yellow 630 Antibody Labeling Kit *Microscale Optimized for Labeling 50 μg Antibody Per Reaction*
ReadiLink™ Rapid mFluor™ Red 700 Antibody Labeling Kit *Microscale Optimized for Labeling 50 μg Antibody Per Reaction*
ReadiLink™ Rapid mFluor™ Red 780 Antibody Labeling Kit *Microscale Optimized for Labeling 50 μg Antibody Per Reaction*
ReadiLink™ Rapid iFluor® 350 Antibody Labeling Kit *Microscale Optimized for Labeling 50 μg Antibody Per Reaction*
ReadiLink™ Rapid iFluor® 555 Antibody Labeling Kit *Microscale Optimized for Labeling 50 μg Antibody Per Reaction*
ReadiLink™ Rapid iFluor® 594 Antibody Labeling Kit *Microscale Optimized for Labeling 50 μg Antibody Per Reaction*
ReadiLink™ Rapid iFluor® 647 Antibody Labeling Kit *Microscale Optimized for Labeling 50 μg Antibody Per Reaction*
ReadiLink™ Rapid iFluor® 680 Antibody Labeling Kit *Microscale Optimized for Labeling 50 μg Antibody Per Reaction*
ReadiLink™ Rapid iFluor® 700 Antibody Labeling Kit *Microscale Optimized for Labeling 50 μg Antibody Per Reaction*
ReadiLink™ Rapid iFluor® 750 Antibody Labeling Kit *Microscale Optimized for Labeling 50 μg Antibody Per Reaction*
ReadiLink™ Rapid iFluor® 488 Antibody Labeling Kit *Microscale Optimized for Labeling 50 μg Antibody Per Reaction*
ReadiLink™ Rapid iFluor® 633 Antibody Labeling Kit *Microscale Optimized for Labeling 50 μg Antibody Per Reaction*
ReadiLink™ Rapid iFluor® 790 Antibody Labeling Kit *Microscale Optimized for Labeling 50 μg Antibody Per Reaction*
ReadiLink™ Rapid FITC Antibody Labeling Kit *Microscale Optimized for Labeling 50 μg Antibody Per Reaction*
ReadiLink™ Rapid trFluor™ Eu Antibody Labeling Kit *Microscale Optimized for Labeling 50 ug Antibody Per Reaction*
ReadiLink™ Rapid trFluor™ Tb Antibody Labeling Kit *Microscale Optimized for Labeling 50 ug Antibody Per Reaction*
ReadiLink™ Protein Conjugation Stop Buffer
ReadiLink™ BSA Conjugation Kit
ReadiLink™ KLH Conjugation Kit
ReadiLink™ Rapid Cy3 Antibody Labeling Kit *Microscale Optimized for Labeling 50 μg Antibody Per Reaction*
ReadiLink™ Rapid Cy5 Antibody Labeling Kit *Microscale Optimized for Labeling 50 μg Antibody Per Reaction*
ReadiLink™ Rapid Cy7 Antibody Labeling Kit *Microscale Optimized for Labeling 50 μg Antibody Per Reaction*
ReadiLink™ xtra Rapid iFluor® 350 Antibody Labeling Kit *BSA-Compatible*
ReadiLink™ xtra Rapid iFluor® 488 Antibody Labeling Kit *BSA-Compatible*
ReadiLink™ xtra Rapid iFluor® 555 Antibody Labeling Kit *BSA-Compatible*
ReadiLink™ xtra Rapid iFluor® 594 Antibody Labeling Kit *BSA-Compatible*
ReadiLink™ xtra Rapid iFluor® 647 Antibody Labeling Kit *BSA-Compatible*
ReadiLink™ xtra Rapid iFluor® 750 Antibody Labeling Kit *BSA-Compatible*
ReadiLink™ xtra Rapid FITC Antibody Labeling Kit *BSA-Compatible*
ReadiLink™ xtra Rapid Cy3 Antibody Labeling Kit *BSA-Compatible*
ReadiLink™ xtra Rapid Cy5 Antibody Labeling Kit *BSA-Compatible*
ReadiLink™ xtra Rapid Cy7 Antibody Labeling Kit *BSA-Compatible*
ReadiLink™ xtra Rapid XFD594 Antibody Labeling Kit *BSA-Compatible, XFD594 Same Structure to Alexa Fluor™ 594*
ReadiLink™ Rapid XFD488 Antibody Labeling Kit *XFD488 Same Structure to Alexa Fluor™ 488*
ReadiLink™ Rapid XFD555 Antibody Labeling Kit *XFD555 Same Structure to Alexa Fluor™ 555*
ReadiLink™ Rapid XFD594 Antibody Labeling Kit *XFD594 Same Structure to Alexa Fluor™ 594*
ReadiLink™ Rapid XFD647 Antibody Labeling Kit *XFD647 Same Structure to Alexa Fluor™ 647*
ReadiLink™ Rapid XFD750 Antibody Labeling Kit *XFD750 Same Structure to Alexa Fluor™ 750*
ReadiLink™ iFluor® 488 Nick Translation dsDNA Labeling Kit
ReadiLink™ iFluor® 555 Nick Translation dsDNA Labeling Kit
ReadiLink™ iFluor® 647 Nick Translation dsDNA Labeling Kit
ReadiLink™ Cy3 Nick Translation dsDNA Labeling Kit
ReadiLink™ Cy5 Nick Translation dsDNA Labeling Kit
ReadiLink™ Biotin Nick Translation dsDNA Labeling Kit
ReadiLink™ DIG (Digoxigenin) Nick Translation dsDNA Labeling Kit
ReadiLink™ iFluor® 488 Oligo and ssDNA Labeling Kit
ReadiLink™ iFluor® 555 Oligo and ssDNA Labeling Kit
ReadiLink™ iFluor® 647 Oligo and ssDNA Labeling Kit
ReadiLink™ Cy3 Oligo and ssDNA Labeling Kit
ReadiLink™ Cy5 Oligo and ssDNA Labeling Kit
ReadiLink™ Biotin Oligo and ssDNA Labeling Kit
ReadiLink™ DIG (Digoxigenin) Oligo and ssDNA Labeling Kit
ReadiLink™ xtra Rapid XFD488 Antibody Labeling Kit *BSA-Compatible, XFD488 Same Structure to Alexa Fluor™ 488*
ReadiLink™ xtra Rapid XFD555 Antibody Labeling Kit *BSA-Compatible, XFD555 Same Structure to Alexa Fluor™ 555*
ReadiLink™ xtra Rapid XFD647 Antibody Labeling Kit *BSA-Compatible, XFD647 Same Structure to Alexa Fluor™ 647*
ReadiLink™ xtra Rapid XFD750 Antibody Labeling Kit *BSA-Compatible, XFD750 Same Structure to Alexa Fluor™ 750*
ReadiLink™ iFluor® 488 FISH Fluorescence Imaging Kit
ReadiLink™ iFluor® 555 FISH Fluorescence Imaging Kit
ReadiLink™ iFluor® 647 FISH Fluorescence Imaging Kit
ReadiLink™ Rapid iFluor® 350 Antibody Labeling Kit *Production Scale*
ReadiLink™ Rapid iFluor® 488 Antibody Labeling Kit *Production Scale*
ReadiLink™ Rapid iFluor® 555 Antibody Labeling Kit *Production Scale*
ReadiLink™ Rapid iFluor® 594 Antibody Labeling Kit *Production Scale*
ReadiLink™ Rapid iFluor® 647 Antibody Labeling Kit *Production Scale*
ReadiLink™ Rapid iFluor® 750 Antibody Labeling Kit *Production Scale*
ReadiLink™ Rapid FITC Antibody Labeling Kit *Production Scale*
ReadiLink™ Rapid Cy3 Antibody Labeling Kit *Production Scale*
ReadiLink™ Rapid Cy5 Antibody Labeling Kit *Production Scale*
ReadiLink™ Rapid XFD488 Antibody Labeling Kit *Production Scale*
ReadiLink™ Rapid XFD555 Antibody Labeling Kit *Production Scale*
ReadiLink™ Rapid XFD594 Antibody Labeling Kit *Production Scale*
ReadiLink™ Rapid Cy7 Antibody Labeling Kit *Production Scale*
ReadiLink™ Rapid XFD647 Antibody Labeling Kit *Production Scale*
ReadiLink™ Rapid XFD750 Antibody Labeling Kit *Production Scale*
ReadiLink™ Psoralen-A17-Biotin
ReadiLink™ Rapid mFluor™ Violet 610 Antibody Labeling Kit *Microscale Optimized for Labeling 50 µg Antibody Per Reaction*
Show More (72)

OverviewpdfSDSpdfProtocol


Biotin is widely used for labeling biomolecules, in particular, antibodies. Our ReadiLink™ Protein Biotinylation Kit is optimized for the preparation of biotin-labeled IgG for enzyme immunoassay (EIA). It uses biotin succinimidyl ester that reacts with the amino groups of IgG and other biomolecules. This kit comes with all the necessary reagents for labeling and purification. On our hands, 3 to 6 biotin molecules can be conjugated to each IgG molecule depending on the molecular weight and lysine residues available on the IgG molecule. The kit can be used for 2 conjugation reactions. For each conjugation reaction the material can label up to 1 mg protein. The entire process only takes less than an hour.

Components


Example protocol


AT A GLANCE

Protocol Summary
  1. Add 20 µl Reaction Buffer (Component B) into target protein (200 µl)
  2. Add the protein solution into ReadiLink™ Biotin SE (Component A)
  3. Incubate at room temperature for 30-60 minutes
  4. Purify the conjugate by spin column 
Important      Upon receipt, store ReadiLink™ Biotin SE (Component A) at -20 oC, kept from moisture. Store other components at room temperature. Do not freeze Reaction Buffer (Component B) and Spin Column (Component C). Warm all the components before opening, and immediately prepare the required solutions before starting the conjugation. You might need further optimization for your protein labeling since this SOP was developed for Goat anti-Rabbit IgG labeling.

PREPARATION OF WORKING SOLUTION

Protein working solution
For labeling 1 mg target protein (assuming the target protein concentration is 5 mg/mL), mix 20 µL (10% of the total reaction volume) of Reaction Buffer (Component B) with 200 µL of the target protein solution.
Note     If you have a different protein concentration, adjust the protein volume accordingly to make ~1 mg protein available for this labeling reaction.
Note     The pH of the protein solution should be 8.5 ± 0.5. If the pH of the protein solution is lower than 8.0, adjust the pH to the range of 8.0-9.0 using Reaction Buffer (Component B) or saturated sodium bicarbonate solution.
Note     The protein should be dissolved in 1X phosphate buffered saline (PBS), pH 7.2-7.4. If the protein is dissolved in Tris or glycine buffer, it must be dialyzed against 1X PBS, pH 7.2-7.4, to remove free amines or ammonium salts (such as ammonium sulfate and ammonium acetate) that are widely used for protein precipitation.
Note     Impure antibodies or antibodies stabilized with bovine serum albumin (BSA) or gelatin might not be labeled well. The presence of sodium azide or thimerosal might also interfere with the conjugation reaction. Sodium azide or thimerosal can be removed by dialysis or spin column for optimal labeling results.
Note     The conjugation efficiency is significantly reduced if the protein concentration is less than 2 mg/mL. For optimal labeling efficiency, the final protein concentration range of 2-10 mg/mL is recommended.

SAMPLE EXPERIMENTAL PROTOCOL

Run conjugation reaction
  1. Add the protein working solution into the vial of ReadiLink™ Biotin SE (Component A), and mix them well by repeatedly pipetting for a few times or vortex the vial for a few seconds.
  2. Keep the conjugation reaction mixture at room temperature for 30 - 60 minutes.
    Note     The conjugation reaction mixture can be rotated or shaken for longer time if desired. 

Prepare spin column for sample purification
  1. Invert the provided spin column (Component C) several times to re-suspend the settled gel and remove any bubbles.
  2. Snap off the tip and place the column in a washing tube (2 mL, not provided). Remove the cap to allow the excess packing buffer to drain by gravity to the top of the gel bed. If column does not begin to flow, push cap back into column and remove it again to start the flow. Discard the drained buffer, and then place the column back into the Washing Tube. However, centrifuge immediately if the column is placed into a 12 x 75 mm test tube (not provided).
  3. Centrifuge for 1 minutes in a swinging bucket centrifuge at 1,000 x g (see Centrifugation Notes section) to remove the packing buffer. Discard the buffer.
  4. Apply 1-2 mL 1X PBS (pH 7.2-7.4) to the column. After each application of PBS, let the buffer drain out by gravity, or centrifuge the column for 2 minutes to remove the buffer. Discard the buffer from the collection tube. Repeat this process for 3-4 times.
  5. Centrifuge for 2 minutes in a swinging bucket centrifuge at 1,000 x g (see Centrifugation Notes section) to remove the packing buffer. Discard the buffer. 

Purify the conjugates
  1. Place the column (from Step Prepare spin column for sample purification) in a clean Collecting Tube (1.5 mL, not provided). Carefully load the sample (100-500µL, from Step conjugation reaction) directly to the center of the column.
  2. After loading the sample, add 300 µL of 1X PBS (pH 7.2-7.4) to make the total volume of 220 µL to 520 µL. Centrifuge the column for 5-6 minutes at 1,000 x g, and collect the solution that contains the desired biotin-labelled protein. 

Storage of Protein Conjugate
The antibody conjugate should be stored at > 0.5 mg/mL in the presence of a carrier protein (e.g., 0.1% bovine serum albumin). The conjugate solution could be stored at 4 °C for two months without significant change when stored in the presence of 2 mM sodium azide and kept from light. For longer storage, the protein conjugates could be lyophilized or divided into single-used aliquotes and stored at ≤ –60 °C.

Centrifugation Notes

Spin column (Component C) can fit into 2 mL microcentrifuge tubes or 12 x 75 mm test tubes for sample collection during centrifugation. Use the 2 mL microtube with the columns for the initial column equilibration step. Swinging bucket centrifuges capable of generating a minimum force of 1,000 x g are suitable for Bio-Spin column use. The gravitational force created at a particular revolution speed is a function of the radius of the microcentrifuge rotor. Consult the swinging bucket centrifuge instruction manual for the information about conversion from revolutions per minute (RPM) to centrifugal or g-force. Alternatively, use the following equation to calculate the speed in RPM required to reach the gravitational force of 1,000 x g. RCF (x g) = (1.12 x 10-5)×(RPM)×2×r (RCF is the relative centrifugal force, r is the radius in centimeters measured from the center of the rotor to the middle of the Bio-Spin column, and RPM is the speed of the rotor).

Images


Citations


View all 4 citations: Citation Explorer
Costunolide covalently targets NACHT domain of NLRP3 to inhibit inflammasome activation and alleviate NLRP3-driven inflammatory diseases
Authors: Xu, Haowen and Chen, Jiahao and Chen, Pan and Li, Weifeng and Shao, Jingjing and Hong, Shanshan and Wang, Yi and Chen, Lingfeng and Luo, Wu and Liang, Guang
Journal: Acta Pharmaceutica Sinica B (2022)
A low-cost, high-performance system for fluorescence lateral flow assays
Authors: Lee, Linda G and Nordman, Eric S and Johnson, Martin D and Oldham, Mark F
Journal: Biosensors (2013): 360--373
Implementation of P22 viral capsids as nanoplatforms
Authors: Kang, Sebyung and Uchida, Masaki and O'Neil, Alison and Li, Rui and Prevelige, Peter E and Douglas, Trevor
Journal: Biomacromolecules (2010): 2804--2809
Calcium-dependent activation of transglutaminase 2 by nanosecond pulsed electric fields
Authors: Morotomi-Yano, Keiko and Yano, Ken-ichi
Journal: FEBS Open Bio

References


View all 78 references: Citation Explorer
Evaluation of a new biotin-DOTA conjugate for pretargeted antibody-guided radioimmunotherapy (PAGRIT((R)))
Authors: Urbano N, Papi S, Ginanneschi M, De Santis R, Pace S, Lindstedt R, Ferrari L, Choi S, Paganelli G, Chinol M.
Journal: Eur J Nucl Med Mol Imaging. (2006)
A biotin-protein bond with stability in plasma
Authors: Bogusiewicz A, Mock NI, Mock DM.
Journal: Anal Biochem (2005): 98
Instability of the biotin-protein bond in human plasma
Authors: Bogusiewicz A, Mock NI, Mock DM.
Journal: Anal Biochem (2004): 156
Design, synthesis, and evaluation of 5'-S-aminoethyl-N(6)- azidobenzyl-5'-thioadenosine biotin conjugate: a bifunctional photoaffinity probe for the es nucleoside transporter
Authors: Addo JK, Buolamwini JK.
Journal: Bioconjug Chem (2004): 536
Biotin is endogenously expressed in select regions of the rat central nervous system
Authors: McKay BE, Molineux ML, Turner RW.
Journal: J Comp Neurol (2004): 86
Probing the interaction of the biotin-avidin complex with the relaxivity of biotinylated Gd-DTPA
Authors: Langereis S, Kooistra HA, van Genderen MH, Meijer EW.
Journal: Org Biomol Chem (2004): 1271
Immunoassay of total prostate-specific antigen using europium(III) nanoparticle labels and streptavidin-biotin technology
Authors: Huhtinen P, Soukka T, Lovgren T, Harma H.
Journal: J Immunol Methods (2004): 111
Volume of RBCs, 24- and 48-hour posttransfusion survivals, and the lifespan of (51)Cr and biotin-X-N-hydroxysuccinimide (NHS)-labeled autologous baboon RBCs: effect of the anticoagulant and blood pH on (51)Cr and biotin-X-NHS elution in vivo
Authors: Valeri CR, Pivacek LE, Cassidy GP, Ragno G.
Journal: Transfusion (2002): 343
Endogenous biotin staining in a subset of spinal neuronal cell bodies: a potential confounding factor for neuroanatomical studies
Authors: Berkowitz A., undefined
Journal: Brain Res (2002): 98
End-labeling of long DNA fragments with biotin and detection of DNA immobilized on magnetic beads
Authors: Xu H, Zhang S, Liu D, Liang CC.
Journal: Mol Biotechnol (2001): 183