Amplite® Colorimetric Nitrite Quantification Assay Kit
Product key features
- Optimized Reagents: Includes all necessary components for efficient and reproducible results.
- Simple Protocol: Quick and straightforward procedure with minimal hands-on time.
- High Compatibility: Suitable for a variety of biological samples, including cell culture supernatants and serum.
Product description
The Amplite® Colorimetric Nitrite Quantification Assay Kit offers a sensitive colorimetric method for quantifying nitrite levels in various biological samples. Nitrite serves as a key indicator of nitric oxide (NO) production through the nitrate-nitrite-NO pathway, which plays a pivotal role in vasodilation, immune function, and cellular signaling. Precise nitrite quantification is crucial for studies investigating nitric oxide biology and its role in both physiological and pathological processes.
This kit employs a colorimetric detection strategy where nitrite reacts with a developer to produce a visible color change. The resulting color intensity, measurable using a standard absorbance microplate reader, is directly proportional to the nitrite concentration in the sample. The assay’s reagents are optimized for straightforward preparation, enabling rapid, reliable results with minimal sample processing. The kit is compatible with various sample types, such as cell culture media and serum, making it an essential tool for researchers examining nitric oxide metabolism and related biological mechanisms.
Example protocol
AT A GLANCE
- Prepare test samples along with serially diluted nitrite standards (75 μL).
- Add Griess Reagent working solution (75 μL).
- Incubate at RT for 10 minutes.
- Measure the absorbance at 548 nm.
- In a 1 cm path length cuvette, mix test samples or serially diluted nitrite standards with Griess Reagents:
- 2.6 mL of deionized water
- 100 µL of Griess Reagent
- 300 µL of the nitrite-containing sample
- Incubate at RT for 10 minutes.
- Measure the absorbance at 548 nm.
Important note: Thaw all the kit components at room temperature before starting the experiment.
PREPARATION OF STANDARD SOLUTIONS
https://www.aatbio.com/tools/serial-dilution/21666
PREPARATION OF WORKING SOLUTION
Add 1 mL Griess Reagents (Component A) to 6.5 mL of distilled water. Mix well, protected from light.
Note: Working solution should be prepared fresh for each experiment.
SAMPLE EXPERIMENTAL PROTOCOL
- Prepare Nitrite Standards (STD1-7), blank controls (BL), and test samples (TS) according to the layout provided in Tables 1 and 2. For a 384-well plate, use 37.5 µL of reagent per well instead of 75 µL.
- Add 75 µL of Griess Reagent working solution to each well of blank control, nitrite positive control and test samples. For a 384-well plate, add 37.5 µL of nitrite working solution into each well instead.
- Incubate at RT for 10 minutes, protected from light.
- Measure absorbance at 548 nm.
Table 1. Layout of Nitrite standards and test samples in a clear bottom 96-well microplate. STD= Nitrite Standards (STD1-STD7, 1.55 to 100 µM), BL=Blank Control, TS=Test Samples.
Cell content | BL | Positive Control | TS |
STD 1 | STD 1 | ... | ... |
STD 2 | STD 2 | ... | ... |
STD 3 | STD 3 | ||
STD 4 | STD 4 | ||
STD 5 | STD 5 | ||
STD 6 | STD 6 | ||
STD 7 | STD 7 |
Note: Nitrite concentrations in the test samples (TS) should be within the linear range of the assay (~1-100 µM).
Table 2. Reagent composition for each well.
Well | Volume | Reagent |
STD1-STD7 | 75 µL | Serial Dilutions (1.55 to 100 µM) |
BL | 75 µL | Distilled water |
TS | 75 µL | Test Sample |
Nitrite Standard Dilution:
Add 4 μL of 50 mM nitrite standard solution (component B) into 2mL of distilled water to get 100 µM nitrite standard solution (STD7). Take 1 ml (STD7) and perform 2X serial dilutions in distilled water to get serially diluted Nitrite from 50 µM, 25 µM, 12.5 µM, 6.25 µM, 3.13 µM and 1.56 µM (STD6 to STD1).
Assay protocol:
Add the following in a cuvette with 1 cm path length:
- 2.6 mL of deionized water
- 100 µL of Griess Reagent (Component A)
- 300 µL of the nitrite-containing sample
Note: Nitrite concentrations in the test samples (TS) should be within the linear range of the assay (1-100 µM).Incubate RT for 10 min.
Measure absorbance at 548 nm.
References
Authors: Sun, Jingbo and Long, Tiantian and Chen, Zihan and Luo, Hongmei and Cao, Jiafeng and Xu, Dong and Yuan, Zhiqin
Journal: Analytica chimica acta (2025): 343524
Authors: Mavropoulos, Simeon K B and Zaiton, Rabi and Basic, Amina and Dahlén, Gunnar
Journal: Journal of oral microbiology (2025): 2517039
Authors: Zhang, Man and Truver, Michael T and Hoyer, Jennifer L and Chronister, Chris W and Goldberger, Bruce A
Journal: Journal of analytical toxicology (2023): 746-749
Authors: Taweekarn, Tarawee and Wongniramaikul, Worawit and Boonkanon, Chanita and Phatthanawiwat, Kharittha and Pasitsuparoad, Pakorn and Ritchie, Raymond J and Choodum, Aree
Journal: Food chemistry (2022): 133085
Authors: Hakobyan, Lusine and Monforte-Gómez, Belén and Moliner-Martínez, Yolanda and Molins-Legua, Carmen and Campíns-Falcó, Pilar