logo
AAT Bioquest

ReadiUse™ Bio-Gel P-6 spin column

<strong>Prepacked ReadiUse&trade; Bio-Gel P6 Spin Column.</strong> <br />The column was packed with P-6 DG in&nbsp;PBS buffer for sample volume 50~100 uL. The MW limit is ~6000 and large molecules like proteins (MW&nbsp;&gt; 15,000) will be eluted with a buffer.
<strong>Prepacked ReadiUse&trade; Bio-Gel P6 Spin Column.</strong> <br />The column was packed with P-6 DG in&nbsp;PBS buffer for sample volume 50~100 uL. The MW limit is ~6000 and large molecules like proteins (MW&nbsp;&gt; 15,000) will be eluted with a buffer.
<strong>Prepacked ReadiUse&trade; Bio-Gel P6 Spin Column.</strong> <br />The column was packed with P-6 DG in&nbsp;PBS buffer for sample volume 50~100 uL. The MW limit is ~6000 and large molecules like proteins (MW&nbsp;&gt; 15,000) will be eluted with a buffer.
Ordering information
Price
Catalog Number
AvailabilityIn stock
Unit Size
Quantity
Add to cart
Additional ordering information
Telephone1-800-990-8053
Fax1-800-609-2943
Emailsales@aatbio.com
InternationalSee distributors
Bulk requestInquire
Custom sizeInquire
ShippingStandard overnight for United States, inquire for international
Request quotation
Storage, safety and handling
Intended useResearch Use Only (RUO)
StorageRoom temperature (10-25 °C)
Related products
ReadiUse™ Preactivated APC-iFluor® 700 Tandem
ReadiUse™ Preactivated APC-iFluor® 750 Tandem
ReadiUse™ Preactivated PE-iFluor® 647 Tandem
ReadiUse™ Preactivated PE-iFluor® 750 Tandem
ReadiUse™ ABTS Substrate Solution *Optimized for ELISA Assays with HRP Conjugates*
ReadiUse™ TMB Substrate Solution *Optimized for ELISA Assays with HRP Conjugates*
ReadiUse™ hydrogen peroxide solution *50 mM calibrated and stabilized solution*
ReadiUse™ Preactivated HRP NHS ester
ReadiUse™ NADPH Regenerating Kit
ReadiUse™ NADP Regenerating Kit
ReadiUse™ TCA Deproteinization Sample Preparation Kit
ReadiUse™ microscope mounting solution
ReadiUse™ 4% formaldehyde fixation solution
ReadiUse™ mammalian cell lysis buffer *5X*
ReadiUse™ probenecid, sodium salt *Water-soluble*
ReadiUse™ probenecid *25 mM stabilized aqueous solution*
ReadiUse™ CFSE [5-(and 6)-Carboxyfluorescein diacetate, succinimidyl ester] *CAS 150347-59-4*
ReadiUse™ Preactivated PE
ReadiUse™ Preactivated APC
ReadiUse™ Preactivated PE-Cy5 Tandem
ReadiUse™ Preactivated PE-Cy5.5 Tandem
ReadiUse™ Preactivated PE-Cy7 Tandem
ReadiUse™ Preactivated PE-Texas Red Tandem
ReadiUse™ Preactivated APC-Cy5.5 Tandem
ReadiUse™ Preactivated APC-Cy7 Tandem
ReadiUse™ TCEP removal solution
ReadiUse™ WST-8 *50 mM aqueous solution*
ReadiUse™ Rapid Luminometric ATP Assay Kit
ReadiUse™ PE [R-Phycoerythrin] *Ammonium Sulfate-Free*
ReadiUse™ CL-APC [Cross linked-Allophycocyanin] *Ammonium Sulfate-Free*
ReadiUse™ Preactivated PE-iFluor® 594 Tandem
ReadiUse™ Cell Detaching Buffer
ReadiUse™ DRAQ5 Staining Solution *5 mM in Water*
ReadiUse™ Staurosporine * 1 mM DMSO stock solution*
ReadiUse™ bacterial cell lysis buffer *5X*
ReadiUse™ 10% Triton X-100 *Hydrogen Peroxide-and Carbonyl-Free*
ReadiUse™ Preactivated PE-iFluor® 700 Tandem
ReadiUse™ dNTP Mix *10 mM*
ReadiUse™ Viral RNA Lysis Buffer
ReadiUse™ Tyramide (TSA)/Styramide (PSA) Optimized Reaction Buffer
ReadiUse™ Preactivated PerCP
ReadiUse™ Preactivated PerCP-Cy5.5 Tandem
ReadiUse™ Preactivated PE-iFluor® 660 Tandem
ReadiUse™ 10KD Spin Filter
ReadiUse™ Preactivated APC-iFluor® 800 Tandem
ReadiUse™ 1 Kb Plus DNA Ladder
ReadiUse™ GeneRuler 1 kb DNA Ladder
ReadiUse™ 100 bp DNA Ladder
ReadiUse™ ddNTP Terminator Mix *10 mM*
ReadiUse™ dNTP Mix Set *10 mM PCR Grade*
ReadiUse™ Preactivated HRP maleimide
ReadiUse™ Stayright™ Purple *HRP Chromogen Premixed with Hydrogen Peroxide*
ReadiUse™ Disposable PD-10 Desalting Column
ReadiUse™ Preactivated APC Maleimide [Activated Allophycocyanin]
ReadiUse™ Preactivated PE Maleimide [Activated R-Phycoerythrin]
ReadiUse™ 6-Color Human TBNK Antibody Kit *Dry Reagent Format*
ReadiUse™ MTS Reagent *5 mM aqueous solution*
ReadiUse™ Preactivated PE-Texas Red Maleimide
ReadiUse™ Preactivated PE-Cy5 Maleimide
ReadiUse™ Preactivated PE-Cy5.5 Maleimide
ReadiUse™ Preactivated PE-Cy7 Maleimide
ReadiUse™ Preactivated APC-AF700 Maleimide
ReadiUse™ Preactivated APC-Cy5.5 Maleimide
ReadiUse™ Preactivated APC-Cy7 Maleimide
ReadiUse™ Preactivated PerCP Maleimide
ReadiUse™ Preactivated PerCP-Cy5.5 Maleimide
ReadiUse™ Preactivated PerCP-Cy7 Maleimide
ReadiUse™ PCR Reaction Buffer
ReadiUse™ Universal Kinase Reaction Stopping Buffer
ReadiUse™ Yeast Cell Lysis Buffer *5X*
ReadiUse™ ATP Reference Standard *10 mM Aqueous Solution*
Show More (61)

OverviewpdfSDSpdfProtocol


ReadiUse™ Spin chromatography columns are packed with polyacrylamide P-6-DG matrices for buffer exchange and desalting applications. When applying a material to the spin column, the substances smaller than the column's exclusion limit (MW~6000) will be retained in the column and large molecules like proteins (MW is above 15,000) will be eluted with a buffer. The sample volume ranges from 30 uL to 100 uL. They are compatible with swinging bucket centrifuge with 2.0 ml microcentrifuge tubes or 12 x 75 test tubes.

Example protocol


SAMPLE EXPERIMENTAL PROTOCOL

  1. Invert the Spin Column several times to suspend the settled gel and remove any bubbles.

  2. Snap off the tip and place the column in a microcentrifuge tube (2 mL). Remove the cap to allow the excess packing buffer to drain by gravity until reaching the top of the gel bed. If column does not begin to flow, push cap back into column and remove it again to start the flow. Discard the drained buffer, and then place the column back into the Tube.

  3. Centrifuge for 1 min in a swinging bucket centrifuge at 1,000 x g to remove the packing buffer. Discard the buffer.

  4. Apply 1 mL equilibrium buffer of your choice to the column, let the buffer drain out by gravity, or centrifuge the column for 1 min to remove the buffer. Discard the buffer from the collection tube. Repeat this process for 3-4 times.

  5. Centrifuge for 2 minutes in a swinging bucket centrifuge at 1,000 x g to remove the reaction buffer. Discard the buffer.

  6. Place the column in a clean 2.0 ml microcentrifuge tube or 12 x 75 mm test tube. Carefully apply the sample (20–100 µl) directly to the top center of the column. Sample volume may need be carefully adjusted to reach the best performance.

  7. After loading sample, centrifuge the column for 5 min at 1,000 x g.

  8. Following centrifugation, the purified sample is now in the equilibrium buffer and molecules smaller than the column’s exclusion limit (~6000) will be retained.

  9. Collect the elution, and properly dispose the used column. Note: Spin Column can fit into 2 mL microcentrifuge tubes or 12 x 75 mm test tubes for sample collection during centrifugation. Use the 2 mL microtubes provided with the columns for the initial column equilibration step. Note: Swinging bucket centrifuges capable of generating a minimum force of 1,000 x g are suitable for Bio-Spin column use. The gravitational force created at a particular revolution speed is a function of the radius of the microcentrifuge rotor. Consult the swinging bucket centrifuge instruction manual for the information about conversion from revolutions per minute (RPM) to centrifugal or g-force. Alternatively, use the equation shown below to calculate the speed in RPM required reaching the gravitational force of 1,000 x g.

                                                          CF(g) = (1.12 X 10-5) X (RPM)2 X r                 

RCF = the relative centrifugal force,
RPM = the speed of the rotor
r = the radius in centimeters measured from the center of the rotor to the middle of the Bio-Spin column

Images