logo
Products
Services
Resources
Selection Guides
About
iFluor® 570 Styramide
The Power Styramide™ Signal Amplification (PSA™) system is a highly sensitive method for detecting low-abundance targets in cells and tissues, with fluorescence signals 10-50 times higher than tyramide (TSA) reagents. Paired with our iFluor® dyes, known for their fluorescence intensity, photostability, and water solubility, the iFluor® dye-labeled Styramide™ conjugates achieve precision and sensitivity surpassing standard ICC/IF/IHC methods by over 100 times. PSA™ relies on horseradish peroxidase (HRP) catalytic activity to covalently deposit fluorophores in situ, with radicals displaying higher reactivity than tyramide radicals, making the PSA™ system faster, more robust, and more sensitive than traditional TSA reagents. The Styramide™ conjugates label targets with higher efficiency, leading to significantly greater fluorescence signals while also enabling reduced primary antibody consumption compared to standard methods. iFluor® 570 Styramide is a replacement for Alexa Fluor™ 568 tyramide and similar fluorescent tyramide conjugates or TSA reagents, offering unmatched performance in sensitive imaging applications.
Fluorescence IHC was performed on formaldehyde-fixed, paraffin-embedded human lung adenocarcinoma-positive tissue using PSA™ and TSA amplified methods. First, the tissue sections were stained with rabbit anti-EpCam antibody and then incubated with polyHRP-labeled Goat anti-Rabbit IgG secondary antibody. The signal was developed using either iFluor® 570 Styramide™ (Cat No. 45031) or Alexa Fluor® 568 tyramide stain, respectively, and detected with a Cy3/TRITC filter set. Finally, the nuclei (blue) were counterstained with DAPI (Cat No. 17507).
Fluorescence IHC was performed on formaldehyde-fixed, paraffin-embedded human lung adenocarcinoma-positive tissue using PSA™ and TSA amplified methods. First, the tissue sections were stained with rabbit anti-EpCam antibody and then incubated with polyHRP-labeled Goat anti-Rabbit IgG secondary antibody. The signal was developed using either iFluor® 570 Styramide™ (Cat No. 45031) or Alexa Fluor® 568 tyramide stain, respectively, and detected with a Cy3/TRITC filter set. Finally, the nuclei (blue) were counterstained with DAPI (Cat No. 17507).
CatalogSize
Price
Quantity
45031100 Slides
Price
 
Physical properties

Molecular weight1062.35
SolventDMSO
Spectral properties

Correction factor (260 nm)0.049
Correction factor (280 nm)0.074
Extinction coefficient (cm -1 M -1)
120000
1
Excitation (nm)557
Emission (nm)570
Quantum yield
0.71
1
Storage, safety and handling

H-phraseH303, H313, H333
Hazard symbolXN
Intended useResearch Use Only (RUO)
R-phraseR20, R21, R22
StorageFreeze (< -15 °C); Minimize light exposure
UNSPSC12171501
Instrument settings

Fluorescence microscope
ExcitationCy3/TRITC filter set
EmissionCy3/TRITC filter set
Recommended plateBlack wall/clear bottom
Contact us

Telephone
Fax
Emailsales@aatbio.com
InternationalSee distributors
Bulk requestInquire
Custom sizeInquire
Technical SupportContact us
Request quotationRequest
Purchase orderSend to sales@aatbio.com
ShippingStandard overnight for United States, inquire for international
Page updated on April 11, 2026