logo
Products
Technologies
Applications
Services
Resources
Selection Guides
About
mFluor™ Blue 630 Styramide
The Power Styramide™ Signal Amplification (PSA™) system is a highly sensitive method for detecting low-abundant targets in fluorescent immunocytochemistry (ICC), immunohistochemistry (IHC), and in situ hybridization (ISH). By utilizing bright and photostable mFluor™ dyes, Styramide™ conjugates deliver results of unparalleled sharpness and precision, surpassing the sensitivity of standard ICC/IHC/ISH methods by over 100 times, all the while reducing the consumption of primary antibodies. Like tyramide signal amplification (TSA), PSA™ leverages the catalytic activity of horseradish peroxidase (HRP) to generate high-density labeling of a target protein or nucleic acid sequence in situ. The enhanced reactivity of Styramide™ radicals over tyramide ensures faster more robust labeling of the target, leading to fluorescence signals that are 10-50 times greater than those generated by tyramide (TSA) reagents. The mFluor™ Blue 630 Styramide uses the bright red fluorescent dye mFluor™ Blue 630 (Ex/Em = 470/632 nm) to label targets in situ. mFluor™ Blue 630 is well-excited by the 488 nm laser line and exhibits minimal crosstalk in complex multicolor analysis with blue and green fluorescent probes.
Formalin-fixed, paraffin-embedded (FFPE) human lung tissue was labeled with anti-EpCAM mouse mAb followed by HRP-labeled goat anti-mouse IgG (Cat No. 16728). The fluorescence signal was developed using mFluor™ Blue 630 styramide and detected with a Cy3 filter set.
Formalin-fixed, paraffin-embedded (FFPE) human lung tissue was labeled with anti-EpCAM mouse mAb followed by HRP-labeled goat anti-mouse IgG (Cat No. 16728). The fluorescence signal was developed using mFluor™ Blue 630 styramide and detected with a Cy3 filter set.
CatalogSize
Price
Quantity
45073100 Slides
Price
 
Physical properties

SolventDMSO
Spectral properties

Absorbance (nm)472
Correction factor (260 nm)0.197
Correction factor (280 nm)0.275
Extinction coefficient (cm -1 M -1)
49000
1
Excitation (nm)470
Emission (nm)632
Storage, safety and handling

H-phraseH303, H313, H333
Hazard symbolXN
Intended useResearch Use Only (RUO)
R-phraseR20, R21, R22
StorageFreeze (< -15 °C); Minimize light exposure
UNSPSC12171501
Instrument settings

Fluorescence microscope
Excitation470 nm
Emission632 nm
Recommended plateBlack wall/clear bottom
Contact us

Telephone
Fax
Emailsales@aatbio.com
InternationalSee distributors
Bulk requestInquire
Custom sizeInquire
Technical SupportContact us
Request quotationRequest
Purchase orderSend to sales@aatbio.com
ShippingStandard overnight for United States, inquire for international
Page updated on October 5, 2025