MycoLight™ Ratiometric Bacterial Membrane Potential Kit
Red/Green Fluorescence
AAT Bioquest's MycoLight™ Ratiometric Bacterial Membrane Potential Kit uses a fluorescent sensor that exhibits green fluorescence in both gram-positive and negative bacterial cells in low concentration, but the fluorescence shifts toward red emission at higher cytosolic concentrations due to the dye molecule aggregation caused by larger membrane potentials. The magnitude of membrane potential varies with different bacterial species. For many gram-positive species, the red/green ratio tend to vary with the intensity of the proton gradient while in many gram-negative bacteria the response of the dye does not appear to be proportional to proton gradient intensity. This kit is designed to assay bacterial membrane potentials when the bacterial concentrations are in the range of 105 “ 107 organisms per mL. Stained cells can be monitored fluorimetrically at 510-530 nm (FITC filter) and 600-660 nm (Texas red filter) with excitation at 488 nm, the most common excitation light source.
<p><em>Bacillus </em><em>subtilis </em>was cultured to log phase and diluted to the concentration of 1 x 10<sup>6</sup> cells per mL in PBS. Cells were then treated with 5 &micro;M CCCP for 20 min and incubated with 1X MycoStain It&trade; Green for 30 min before flow cytometry analysis.</p>
<p><em>Bacillus </em><em>subtilis </em>was cultured to log phase and diluted to the concentration of 1 x 10<sup>6</sup> cells per mL in PBS. Cells were then treated with 5 &micro;M CCCP for 20 min and incubated with 1X MycoStain It&trade; Green for 30 min before flow cytometry analysis.</p>
CatalogSize
Price
Quantity
22401200 Tests
Price
 
Spectral properties

Excitation (nm)483
Emission (nm)501
Storage, safety and handling

H-phraseH301, H311, H331
Hazard symbolT
Intended useResearch Use Only (RUO)
R-phraseR23, R24, R25
UNSPSC12352200
Instrument settings

Flow cytometer
Excitation488 nm laser
Emission530/30 nm, 610/20 nm filter
Instrument specification(s)FITC, PE-Texas Red channel

Fluorescence microscope
Excitation510/600 nm
Emission530/660 nm
Recommended plateBlack wall/clear bottom
Instrument specification(s)FITC/Texas Red filter sets
Contact us

Telephone
Fax
Emailsales@aatbio.com
InternationalSee distributors
Bulk requestInquire
Custom sizeInquire
Technical SupportContact us
Request quotationRequest
Purchase orderSend to sales@aatbio.com
ShippingStandard overnight for United States, inquire for international
Page updated on October 8, 2025