Portelite™ Fluorimetric ssDNA Quantitation Kit *Optimized for Cytocite™ and Qubit™ Fluorometers*
Portelite™ Fluorimetric ssDNA Quantitation Kit is designed to rapidly measure single-stranded DNA. The kit has all the essential reagents, including Helixyte™ Green ssDNA reagent, dilution buffer, and prediluted DNA standards. Helixyte™ Green ssDNA reagent is a sensitive fluorescent nucleic acid probe for quantifying oligonucleotides and single-stranded DNA (ssDNA) in solution. Simply dilute the reagent using the buffer provided, add your sample (any volume from 1–20 μL is acceptable), then read the concentration using CytoCite, Qubit® or other hand-held or desk top fluorometers (Qubit® is the trademark of ThermoFisher). The assay is accurate for initial sample concentrations from 50 pg/µL to 200 ng/µL, providing an assay range of 1–200 ng. The assay detects long oligonucleotides or ssDNA. Nucleotides and short oligo nucleotides of six bases or less do not interfere in the quantitation assay. The detection limit is not significantly interfered by the common contaminants in nucleic acid preparations, including salts, urea, ethanol, chloroform, detergents, proteins, nucleotides and short oligonucleotides of six bases. However, double-stranded DNA (dsDNA) and RNA do interfere with the assay as Helixyte™ Green ssDNA reagent binds to dsDNA and RNA to generate additional fluorescence signal. Portelite™ Fluorimetric ssDNA Quantitation Kit is optimized for CytoCite™ and Qubit® fluorometers.
Example protocol
AT A GLANCE
Protocol summary
- Prepare the Helixyte™ Green ssDNA working solution
- Add 190 µL of 1X Helixyte™ Green ssDNA working solution into each 0.2 mL PCR tube
- Add 10 µL of ssDNA Standards or test samples into each tube
- Incubate at room temperature for 2 minutes
- Monitor the fluorescence intensity with CytoCite™ fluorometer or Qubit™ fluorometer
Important
All kit components must be brought to room temperature before starting the experiment.PREPARATION OF WORKING SOLUTION
Helixyte™ Green ssDNA working solution
Make a 200-fold dilution of Helixyte™ Green ssDNA reagent (Component A) with Assay Buffer (Component B). For example, to prepare enough working solution for 5 samples, add 5 μL of Helixyte™ Green ssDNA (Component A) into 1 mL of Assay Buffer (Component B).Note Protect the working solution from light by covering it with foil or placing it in the dark. It’s recommended to prepare the solution in a plastic container rather than a glass container, as the dye may adsorb to the glass surface. For best results, this solution should be used within a few hours after the dilution.
SAMPLE EXPERIMENTAL PROTOCOL
The acceptable range for the sample volume could be 1~20 μL depending on the estimated concentration of the Nucleic Acid sample.
The following protocol is generated based on a sample volume of 10 µL with the DNA concentration in the range of 20~1000 ng /mL.
The following protocol is generated based on a sample volume of 10 µL with the DNA concentration in the range of 20~1000 ng /mL.
- Add 190 µL of 1X Helixyte™ Green ssDNA working solution into each Cytocite™ sample tube (#CCT100) or the equivalent 0.2 mL PCR tube.
Note Use thin-wall, polypropylene, clear 0.2 mL PCR tubes such as AAT Cat#CCT100. - Add 10 µL of ssDNA Standards or test samples into each tube, and then mix by vortexing for 2~3 seconds.
- Incubate all tubes at room temperature for 2 minutes.
- Insert the samples into CytoCite™ or Qubit™ and monitor the fluorescence intensity with the green fluorescence channel. Follow the appropriate procedures for the CytoCite™ Fluorometer. See the link below for detailed instructions: https://devices.aatbio.com/documentation/user-manual-for-cytocite-fluorometer
Preparation Of Standard Calibration Curve
- Perform a 1:2 serial dilution: Add 10 ng/μL ssDNA Standard #2 (Component D) into Assay Buffer (Component B) to get 10, 5, 2.5, 1.25, 0.62, 0.31, 0.15 ng/μL DNA standard dilutions.
- Add 190 µL of the Helixyte™ Green ssDNA working solution into each tube.
- Add 10 µL of standards into a 0.2 mL PCR tube and then mix by vortexing for 2∼3 seconds.
- Incubate the reaction at room temperature for 2 minutes.
- Insert the samples into CytoCite™ and monitor the fluorescence intensity with the green fluorescence channel.
Spectrum
Open in Advanced Spectrum Viewer
Product family
Name | Excitation (nm) | Emission (nm) |
Portelite™ Fluorimetric RNA Quantitation Kit*Optimized for Cytocite™ and Qubit™ Fluorometers* | 509 | 527 |
References
View all 24 references: Citation Explorer
An OliGreen-responsive fluorescence sensor for sensitive detection of organophosphorus pesticide based on its specific selectivity towards T-Hg2+-T DNA structure.
Authors: Zhou, Xiaoyuan and Wang, Chenchen and Wu, Lina and Wei, Wei and Liu, Songqin
Journal: Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy (2021): 119155
Authors: Zhou, Xiaoyuan and Wang, Chenchen and Wu, Lina and Wei, Wei and Liu, Songqin
Journal: Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy (2021): 119155
A novel detection of radon based on its decay product inducing conformational changes of an aptamer probe.
Authors: Long, Minzhi and Deng, Han and Tian, Gang and Song, Chunli and Liu, Hongwen and Shen, Yi and Lv, Changyin
Journal: Analytica chimica acta (2016): 202-7
Authors: Long, Minzhi and Deng, Han and Tian, Gang and Song, Chunli and Liu, Hongwen and Shen, Yi and Lv, Changyin
Journal: Analytica chimica acta (2016): 202-7
Studies of DNA Aptamer OliGreen and PicoGreen Fluorescence Interactions in Buffer and Serum.
Authors: Bruno, John G and Sivils, Jeffrey C
Journal: Journal of fluorescence (2016): 1479-87
Authors: Bruno, John G and Sivils, Jeffrey C
Journal: Journal of fluorescence (2016): 1479-87
Accumulation of single-stranded DNA in Escherichia coli carrying the colicin plasmid pColE3-CA38.
Authors: Morales, Magali and Attai, Hedieh and Troy, Kimberly and Bermudes, David
Journal: Plasmid (2015): 7-16
Authors: Morales, Magali and Attai, Hedieh and Troy, Kimberly and Bermudes, David
Journal: Plasmid (2015): 7-16
Probing the inherent stability of siRNA immobilized on nanoparticle constructs.
Authors: Barnaby, Stacey N and Lee, Andrew and Mirkin, Chad A
Journal: Proceedings of the National Academy of Sciences of the United States of America (2014): 9739-44
Authors: Barnaby, Stacey N and Lee, Andrew and Mirkin, Chad A
Journal: Proceedings of the National Academy of Sciences of the United States of America (2014): 9739-44
Page updated on October 4, 2024