ReadiLink™ Rapid iFluor® 750 Antibody Labeling Kit
Microscale Optimized for Labeling 50 μg Antibody Per Reaction
AAT Bioquest's iFluor® dyes are developed for labeling proteins, in particular, antibodies. These dyes are optimized to have minimal fluorescence quenching effect on proteins and nucleic acids. Our iFluor® 750 dyes have fluorescence excitation and emission maxima close to 750 nm and 780 nm respectively with good photostability. Our in-house comparable studies indicated that our iFluor® 750 dyes are significantly brighter than the corresponding Cy7® and Alexa Fluor® 750. These spectral characteristics make them a superior alternative to Cy7® and Alexa Fluor® 750 (Cy7® and Alexa Fluor® are the trademarks of GE Healthcare and Invitrogen respectively). iFluor® 750 conjugates have been widely used in fluorescence animal imaging applications. ReadiLink™ labeling kits essentially only require 2 simple mixing steps without a column purification needed. iFluor® 750 SE used in this ReadiLink™ kit is reasonably stable and shows good reactivity and selectivity with protein amino groups. The kit has all the essential components for labeling ~2x50 ug antibody. Each of the two vials of iFluor® 750 dye provided in the kit is optimized for labeling ~50 µg antibody. iFluor® 750 SE protein labeling kit provides a convenient method to label monoclonal, polyclonal antibodies or other proteins (>10 kDa) with the iFluor® 750 SE.

 

readilinkworkflow

 

Figure 1. Overview of the ReadiLink™ Rapid Antibody Labeling protocol. In just two simple steps, and with no purification necessary, covalently label microgram amounts of antibodies in under an hour.

HL-60 cells were incubated with (red) or without (green) anti-human HLA-ABC (W6/32 mAb). Cells were then incubated with goat anti-mouse IgG labeled using the ReadiLink™ Rapid iFluor® 750 Antibody Labeling Kit (Cat No. 1250). The fluorescence signal was monitored using ACEA NovoCyte flow cytometer in the APC-Cy7 channel.
HL-60 cells were incubated with (red) or without (green) anti-human HLA-ABC (W6/32 mAb). Cells were then incubated with goat anti-mouse IgG labeled using the ReadiLink™ Rapid iFluor® 750 Antibody Labeling Kit (Cat No. 1250). The fluorescence signal was monitored using ACEA NovoCyte flow cytometer in the APC-Cy7 channel.
CatalogSize
Price
Quantity
12502 Labelings
Price
 
Spectral properties

Correction factor (260 nm)0.044
Correction factor (280 nm)0.039
Correction factor (565 nm)0.0250
Correction factor (650 nm)0.1413
Extinction coefficient (cm -1 M -1)
275000
1
Excitation (nm)757
Emission (nm)779
Quantum yield
0.12
1
Storage, safety and handling

H-phraseH303, H313, H333
Hazard symbolXN
Intended useResearch Use Only (RUO)
R-phraseR20, R21, R22
UNSPSC12171501
Contact us

Telephone
Fax
Emailsales@aatbio.com
InternationalSee distributors
Bulk requestInquire
Custom sizeInquire
Technical SupportContact us
Request quotationRequest
Purchase orderSend to sales@aatbio.com
ShippingStandard overnight for United States, inquire for international
Page updated on September 25, 2025