logo
Products
Technologies
Applications
Services
Resources
Selection Guides
About
ReadiLink™ Rapid mFluor™ Red 700 Antibody Labeling Kit
Microscale Optimized for Labeling 50 μg Antibody Per Reaction
AAT Bioquest's mFluor™ dyes are developed for flow cytometry-focused applications. These dyes have large Stokes Shifts, and can be well excited by the laser lines of flow cytometers (e.g., 405 nm, 488 nm and 633 nm). mFluor™ Red 700 dyes have fluorescence excitation and emission maxima of ~657 nm and ~700 nm respectively. Like Alexa Fluor 700-APC tandem, it has strong absorption at 633 nm, making its conjugates readily excitable by 633 nm red laser. These spectral characteristics make mFluor™ Red 700 an excellent alternative to Alexa Fluor 700-APC tandem. mFluor™ Red 700 is a small organic molecule that is much easier to use than the Alexa Fluor 700-APC tandem. mFluor™ Red 700 SE is reasonably stable and shows good reactivity and selectivity with protein amino groups. This kit has all the essential components to perform two separate labeling reactions with no column purification needed. Each of the two vials of mFluor™ Red 700 provided in the kit is optimized for labeling ~50 µg antibody. mFluor™ Red 700 antibody labeling kit provides a convenient method to label small amounts of monoclonal, polyclonal antibodies or other proteins (>10 kDa) with the mFluor™ Red 700 dye.

 

readilinkworkflow

 

Figure 1. Overview of the ReadiLink™ Rapid Antibody Labeling protocol. In just two simple steps, and with no purification necessary, covalently label microgram amounts of antibodies in under an hour.

HL-60 cells were stained with (Red) or without (Green) 1 µg/mL anti-human HLA-ABC-Biotin (W6/32 mAb). Cells were then incubated with streptavidin labeled using the ReadiLink™ Rapid mFluor™ Red 700 Antibody Labeling Kit (Cat No. 1130). The fluorescence signal was monitored using ACEA NovoCyte flow cytometer in the APC channel.
HL-60 cells were stained with (Red) or without (Green) 1 µg/mL anti-human HLA-ABC-Biotin (W6/32 mAb). Cells were then incubated with streptavidin labeled using the ReadiLink™ Rapid mFluor™ Red 700 Antibody Labeling Kit (Cat No. 1130). The fluorescence signal was monitored using ACEA NovoCyte flow cytometer in the APC channel.
CatalogSize
Price
Quantity
11302 Labelings
Price
 
Spectral properties

Absorbance (nm)651
Correction factor (260 nm)0.135
Correction factor (280 nm)0.127
Extinction coefficient (cm -1 M -1)
295000
1
Excitation (nm)680
Emission (nm)695
Storage, safety and handling

H-phraseH303, H313, H333
Hazard symbolXN
Intended useResearch Use Only (RUO)
R-phraseR20, R21, R22
UNSPSC12171501
Contact us

Telephone
Fax
Emailsales@aatbio.com
InternationalSee distributors
Bulk requestInquire
Custom sizeInquire
Technical SupportContact us
Request quotationRequest
Purchase orderSend to sales@aatbio.com
ShippingStandard overnight for United States, inquire for international
Page updated on November 2, 2025