logo
AAT Bioquest

TAQuest™ qPCR Master Mix for TaqMan Probes *High ROX*

TAQuest™ qPCR Master Mix for TaqMan Probes is a ready-to-use 2X solution optimized for qPCR and 2-step RT-qPCR compatible with TaqMan gene expression assays. The master mix provides all of the essential components including our proprietary TAQuest™ Hot Start Taq DNA Polymerase enzyme and dNTPs in an optimized PCR buffer, except the template, primers and probes. The Hot Start Taq DNA polymerase allows you to set up a PCR reaction at room temperature, thus minimizing non-specific product formation. The optimized composition ensures PCR specificity and sensitivity with all sample types such as genomic, plasmid, viral and cDNA templates. TAQuest™ qPCR Master Mix for TaqMan Probes has been designed to be used for duplex reactions using internal positive controls. This master mix contains a high amount of ROX reference dye.

Example protocol

SAMPLE EXPERIMENTAL PROTOCOL

The following protocol can be used as a guideline.
Note     Thaw the TAQuest™ qPCR Master Mix for TaqMan Probes *High ROX* at room temperature. Vortex qPCR Master Mix thoroughly before use.
  1. Prepare one of the following reaction mixes as indicated in Table 1.
  2. Carefully mix the reagents with a gentle vortex followed by a brief centrifuge.
  3. Set up the plate in the qPCR instrument and run as indicated in Table 2. 
Table 1.Reagents composition per well for each reaction
ComponentsVolume (25 µL/reaction)Volume (50 µL/reaction)Final Conc.
TAQuest™ qPCR Master Mix for TaqMan Probes *High ROX*12.5 µL25 µL1X
Upstream primer, 10 µM0.25-2.5 µL0.5-5.0 µL0.1-1.0 µM
Downstream primer, 10 µM0.25-2.5 µL0.5-5.0 µL0.1-1.0 µM
TaqMan Probes, 10 µM0.25-0.625 µL0.5-1.25 µL100-250 nM
DNA template1-5 µL1-5 µLOptimized conc.
Nuclease-Free Water to25 µL50 µL 
Table 2.Thermal cycling parameters
ParameterPolymerase ActivationPCR (30-40 cycles)
 HoldDenatureAnnealExtend
Temperature95 °C95 °C55-65 °C68-72 °C
Time (m:ss)0:200:301:001:00

References

View all 9 references: Citation Explorer
Resilient SARS-CoV-2 diagnostics workflows including viral heat inactivation.
Authors: Lista, Maria Jose and Matos, Pedro M and Maguire, Thomas J A and Poulton, Kate and Ortiz-Zapater, Elena and Page, Robert and Sertkaya, Helin and Ortega-Prieto, Ana M and Scourfield, Edward and O'Byrne, Aoife M and Bouton, Clement and Dickenson, Ruth E and Ficarelli, Mattia and Jimenez-Guardeño, Jose M and Howard, Mark and Betancor, Gilberto and Galao, Rui Pedro and Pickering, Suzanne and Signell, Adrian W and Wilson, Harry and Cliff, Penelope and Kia Ik, Mark Tan and Patel, Amita and MacMahon, Eithne and Cunningham, Emma and Doores, Katie and Agromayor, Monica and Martin-Serrano, Juan and Perucha, Esperanza and Mischo, Hannah E and Shankar-Hari, Manu and Batra, Rahul and Edgeworth, Jonathan and Zuckerman, Mark and Malim, Michael H and Neil, Stuart and Martinez-Nunez, Rocio Teresa
Journal: PloS one (2021): e0256813
Development of a multiplex TaqMan qPCR assay for simultaneous detection and differentiation of four DNA and RNA viruses from clinical samples of sheep and goats.
Authors: Xu, Xingang and Yang, Feng and Zhang, Qi and Xu, Ying and Huang, Jiali and Fu, Mingzhe and Zhang, Weimin
Journal: Journal of virological methods (2019): 58-64
Evaluation and utilization of preassembled frozen commercial fast real-time qPCR master mixes for detection of cytomegalovirus and BK virus.
Authors: Glover, William A and Atienza, Ederlyn E and Nesbitt, Shannon and Kim, Woo J and Castor, Jared and Cook, Linda and Jerome, Keith R
Journal: Journal of medical virology (2016): 115-9
Real-time stability testing of air-dried primers and fluorogenic hydrolysis probes stabilized by trehalose and xanthan.
Authors: Rombach, Markus and Kosse, Dominique and Faltin, Bernd and Wadle, Simon and Roth, Günter and Zengerle, Roland and von Stetten, Felix
Journal: BioTechniques (2014): 151-5
Frequency-encoded laser-induced fluorescence for multiplexed detection in infrared-mediated quantitative PCR.
Authors: Schrell, Adrian M and Roper, Michael G
Journal: The Analyst (2014): 2695-701
Page updated on October 12, 2024

Ordering information

Price
Unit size
1 mL
5 mL
Catalog Number
Quantity
Add to cart

Additional ordering information

Telephone1-800-990-8053
Fax1-800-609-2943
Emailsales@aatbio.com
InternationalSee distributors
Bulk requestInquire
Custom sizeInquire
Technical SupportContact us
Purchase orderSend to sales@aatbio.com
ShippingStandard overnight for United States, inquire for international
Request quotation

Physical properties

Solvent

Water

Storage, safety and handling

H-phraseH303, H313, H333
Hazard symbolXN
Intended useResearch Use Only (RUO)
R-phraseR20, R21, R22

Storage

Freeze (< -15 °C); Minimize light exposure
UNSPSC12171501

Platform

qPCR

Instrument specification(s)Filter based on probes