Choosing a labeling dye depends on the biomolecule being labeled, the labeling chemistry, the instrument, and the signal performance the assay requires. The reference below covers the major AAT Bioquest dye families, the physical properties that drive dye brightness and sensitivity, the common labeling chemistries, and practical tips for matching a dye to an experiment.
Featured Dye Families
| Dye Family | Targets | Application | Features |
|---|
| iFluor® | Antibodies, proteins, peptides, oligonucleotides | Fluorescence microscopy, flow cytometry | Bright, photostable, UV to NIR emission options |
| mFluor™ | Antibodies, proteins | Flow cytometry | Long Stokes shifts, high-plex experiments |
| Tide Fluor™ | Peptides, oligonucleotides | FRET, molecular beacons | pH-independent fluorescence from pH 3 to pH 11, enhanced water solubility |
| XFD | Antibodies, proteins, peptides, oligonucleotides | Established fluorescence workflows | Identical spectrum to Alexa Fluor® dyes, value pricing |
Labeling Dye Fundamentals
- Quantum yield (Φ) — the fraction of absorbed photons re-emitted as fluorescence
- Extinction coefficient (ε) — how efficiently a dye absorbs photons; this is typically measured at the dye's absorbance maximum
- Fluorescence brightness — approximately calculated as the product of extinction coefficient and quantum yield, but may factor in instrument settings as well
- Photostability — resistance to photobleaching under repeated or prolonged illumination; especially important for fluorescence microscopy, live-cell imaging, time-lapse experiments, and high-content screening
- Stokes shift — the separation between a dye's excitation and emission maxima; a larger Stokes shift reduces excitation bleed-through, simplifies filter selection, and improves signal separation in multiplex assays
- Spectral compatibility — the match between a dye's excitation and emission spectra and the available lasers, light sources, filters, and detectors; good spectral matching raises sensitivity and lowers background and channel crosstalk
Common Labeling Chemistries
| If you are looking to label... | Choose |
|---|
| Primary amines on proteins/antibodies or amine-modified oligos and nucleic acids | NHS ester / SE |
| Reduced thiols (e.g., cysteine on antibodies) | Maleimide |
| Azide-modified targets | DBCO |
| Alkyne-modified targets | Azide |
| Tetrazine partner | TCO |
| TCO-modified targets | Tetrazine |
| Oxidized glycans, aldehydes, or ketones | Hydrazide or hydroxylamine |
- Free reactive dyes — supplied as an activated reagent (NHS ester, maleimide, click handle, and others) for a user-run conjugation, giving full control over the reaction and the degree of labelin
- ReadiLink™ one-step kits — package the reactive dye, buffers, and purification into a single workflow; the sample is combined with the dye and incubated to recover a labeled conjugate with no dialysis or column step.
Selection Tips
- Match the dye's excitation maximum to an available laser or light source
- Choose an emission wavelength compatible with the installed filters and detectors
- Favor high-brightness dyes for low-abundance targets or weakly expressed biomarkers
- Prioritize photostability for microscopy, time-lapse imaging, and repeated scans
- Use appropriate Stokes shifts to reduce bleed-through and improve channel separation in multiplex panels
- Select the reactive group to match the functional group available on the target molecule
All trademarks and registered trademarks mentioned herein are the property of their
respective owners.