FRET moves energy from an excited donor dye to an acceptor that sits within about 1–10 nm of it. The acceptor has to absorb where the donor emits, and the transfer falls off steeply with distance, so a FRET pair reports whether its two labels are close together.
Most probes use a dark quencher as the acceptor. While the quencher is within range it takes the donor's energy and gives it off as heat, so the intact probe is dark. The signal appears when the two are pushed apart: a protease cuts the peptide between them, the polymerase breaks down a TaqMan® probe as it copies the template, or a molecular beacon opens its hairpin to bind its target. A fluorescent acceptor gives a two-color readout instead. When donor and acceptor come together the donor dims and the acceptor lights up in its own channel, and the ratio of the two tells how much of the pair is bound.
Have a donor already? Pick it under Find a Quencher For to see the Tide Quencher™ series rated best for it, whether that donor is FAM, Cy3®, Cy5® or a Tide Fluor™. Instrument Channel groups every dye and quencher by the emission band it is read in. Replacing a dye in an existing probe? Find Alternatives To lists the spectrally equivalent Tide dye for each BHQ®, QSY®, Cy® or Alexa Fluor® dye.
+++ the matched quencher, ++ a close second with Förster distance within about 5% of the best, + works with more background, – not recommended.
| Donor | TQ1 | TQ2 | TQ3 | TQ4 | TQ5 | TQ5.1WS | TQ6 | TQ7 | TQ7.1 / 7.2 | TQ8 |
|---|---|---|---|---|---|---|---|---|---|---|
| EDANS | +++ | ++ | + | – | – | – | – | – | – | – |
| MCA | +++ | + | – | – | – | – | – | – | – | – |
| Tide Fluor™ 1 | +++ | + | – | – | – | – | – | – | – | – |
| FAM / FITC | + | +++ | ++ | + | – | – | – | – | – | – |
| Tide Fluor™ 2 | + | +++ | ++ | + | – | – | – | – | – | – |
| HEX / JOE / TET | – | +++ | +++ | ++ | + | – | – | – | – | – |
| Cy3® / TAMRA / Tide Fluor™ 3 | – | + | +++ | ++ | + | – | – | – | – | – |
| ROX / Texas Red® | – | – | + | +++ | ++ | + | + | – | + | – |
| Tide Fluor™ 4 | – | – | + | +++ | ++ | + | + | – | + | – |
| Cy5® / Tide Fluor™ 5 | – | – | – | + | +++ | +++ | ++ | + | ++ | – |
| Cy5.5® / Tide Fluor™ 6 | – | – | – | – | + | +++ | +++ | ++ | ++ | – |
| Cy7® / Tide Fluor™ 7 | – | – | – | – | – | – | + | +++ | +++ | + |
| Tide Fluor™ 8 | – | – | – | – | – | – | – | ++ | ++ | +++ |
| ICG / iFluor® 820–860 | – | – | – | – | – | – | – | – | – | +++ |
| Assay | Optimize first |
|---|---|
| qPCR probes, molecular beacons, Scorpion® primers | Quenching efficiency, so the intact probe gives a low baseline and a high signal-to-noise ratio. A dark quencher on every probe keeps each signal in its own channel when multiplexing. |
| Protease and caspase substrates | Quenching across a short peptide, then water solubility: WS and HWS quenchers carry sulfonate groups that improve aqueous solubility and reduce aggregation, and labeling a hydrophobic peptide with a TQ-WS can make the peptide itself more soluble. |
| Near-IR probes | An operating window past 650 nm. TQ6WS, TQ7 and TQ8WS are the quenchers that absorb there, where DABCYL's ~470 nm absorbance no longer quenches. |
| TR-FRET immunoassays and screening | A fluorescent acceptor on the donor's emission line, read after a time delay once autofluorescence has decayed. |