logo
AAT Bioquest

Tide Quencher™ 7.2WS succinimidyl ester [TQ7.2WS SE]

Product Image
Product Image
Gallery Image 1
Ordering information
Price
Catalog Number
Unit Size
Quantity
Add to cart
Additional ordering information
Telephone1-800-990-8053
Fax1-800-609-2943
Emailsales@aatbio.com
InternationalSee distributors
Bulk requestInquire
Custom sizeInquire
ShippingStandard overnight for United States, inquire for international
Request quotation
Physical properties
Molecular weight1163.47
SolventDMSO
Storage, safety and handling
H-phraseH303, H313, H333
Hazard symbolXN
Intended useResearch Use Only (RUO)
R-phraseR20, R21, R22
StorageFreeze (< -15 °C); Minimize light exposure
Related products
Tide Quencher™ 2WS acid [TQ2WS acid]
Tide Quencher™ 2WS succinimidyl ester [TQ2WS, SE]
Tide Quencher™ 2WS maleimide [TQ2WS maleimide]
Tide Quencher™ 4WS acid [TQ4WS acid]
Tide Quencher™ 4WS amine [TQ4WS amine]
Tide Quencher™ 4 CPG [TQ4 CPG] *500 Å*
Tide Quencher™ 4 CPG [TQ4 CPG] *1000 Å*
Tide Quencher™ 4WS maleimide [TQ4WS maleimide]
Tide Quencher™ 4WS succinimidyl ester [TQ4WS SE]
Tide Quencher™ 4WS azide [TQ4WS azide]
Tide Quencher™ 4WS alkyne [TQ4WS alkyne]
Tide Quencher™ 5WS acid [TQ5WS acid]
Tide Quencher™ 5WS amine [TQ5WS amine]
Tide Quencher™ 5 CPG [TQ5 CPG] *500 Å*
Tide Quencher™ 5 CPG [TQ5 CPG] *1000 Å*
Tide Quencher™ 5WS maleimide [TQ5WS maleimide]
Tide Quencher™ 5WS succinimidyl ester [TQ5WS SE]
Tide Quencher™ 5WS alkyne [TQ5WS alkyne]
Tide Quencher™ 6WS acid [TQ6WS acid]
Tide Quencher™ 6WS amine [TQ6WS amine]
Tide Quencher™ 6WS maleimide [TQ6WS maleimide]
Tide Quencher™ 6WS succinimidyl ester [TQ6WS SE]
Tide Quencher™ 6WS azide [TQ6WS azide]
Tide Quencher™ 6WS alkyne [TQ6WS alkyne]
Tide Quencher™ 7WS acid [TQ7WS acid]
Tide Quencher™ 7WS amine [TQ7WS amine]
Tide Quencher™ 7WS maleimide [TQ7WS maleimide]
Tide Quencher™ 7WS succinimidyl ester [TQ7WS SE]
Tide Quencher™ 7WS alkyne [TQ7WS alkyne]
Tide Quencher™ 1 azide [TQ1 azide]
Tide Quencher™ 1 alkyne [TQ1 alkyne]
Tide Quencher™ 1 acid [TQ1 acid]
Tide Quencher™ 1 amine [TQ1 amine]
Tide Quencher™ 1 CPG [TQ1 CPG] *500 Å*
Tide Quencher™ 1 CPG [TQ1 CPG] *1000 Å*
Tide Quencher™ 1 maleimide [TQ1 maleimide]
Tide Quencher™ 1 phosphoramidite [TQ1 phosphoramidite]
Tide Quencher™ 1 succinimidyl ester [TQ1 SE]
Tide Quencher™ 2 acid [TQ2 acid]
Tide Quencher™ 2 amine [TQ2 amine]
Tide Quencher™ 2 CPG [TQ2 CPG] *500 Å*
Tide Quencher™ 2 CPG [TQ2 CPG] *1000 Å*
Tide Quencher™ 2 phosphoramidite [TQ2 phosphoramidite]
Tide Quencher™ 2 succinimidyl ester [TQ2 SE]
Tide Quencher™ 2 azide [TQ2 azide]
Tide Quencher™ 2 alkyne [TQ2 alkyne]
Tide Quencher™ 3 acid [TQ3 acid]
Tide Quencher™ 3 amine [TQ3 amine]
Tide Quencher™ 3 CPG [TQ3 CPG] *500 Å*
Tide Quencher™ 3 CPG [TQ3 CPG] *1000 Å*
Tide Quencher™ 3 maleimide [TQ3 maleimide]
Tide Quencher™ 3WS acid [TQ3WS acid]
Tide Quencher™ 3 phosphoramidite [TQ3 phosphoramidite]
Tide Quencher™ 3WS succinimidyl ester [TQ3WS SE]
Tide Quencher™ 3 succinimidyl ester [TQ3 SE]
Tide Quencher™ 3 azide [TQ3 azide]
Tide Quencher™ 3 alkyne [TQ3 alkyne]
Tide Quencher™ 2WS alkyne [TQ2WS alkyne]
Tide Quencher™ 4WS-DBCO [TQ4WS-DBCO]
Tide Quencher™ 5WS azide [TQ5WS azide]
Tide Quencher™ 7WS azide [TQ7WS azide]
Tide Quencher™ 5.1WS acid [TQ5.1WS acid]
Tide Quencher™ 5.1WS amine [TQ5.1WS amine]
Tide Quencher™ 5.1 CPG [TQ5.1 CPG] *500 Å*
Tide Quencher™ 5.1 CPG [TQ5.1 CPG] *1000 Å*
Tide Quencher™ 5.1WS maleimide [TQ5.1WS maleimide]
Tide Quencher™ 5.1WS succinimidyl ester [TQ5.1WS SE]
Tide Quencher™ 5.1WS azide [TQ5.1WS azide]
Tide Quencher™ 5.1WS alkyne [TQ5.1WS alkyne]
Tide Quencher™ 7.1WS acid [TQ7.1WS acid]
Tide Quencher™ 7.1WS amine [TQ7.1WS amine]
Tide Quencher™ 7.1 CPG [TQ7.1 CPG] *500 Å*
Tide Quencher™ 7.1 CPG [TQ7.1 CPG] *1000 Å*
Tide Quencher™ 7.1WS maleimide [TQ7.1WS maleimide]
Tide Quencher™ 7.1WS azide [TQ7.1WS azide]
Tide Quencher™ 7.1WS alkyne [TQ7.1WS alkyne]
Tide Quencher™ 7.2WS acid [TQ7.2WS acid]
Tide Quencher™ 7.2WS amine [TQ7.2WS amine]
Tide Quencher™ 7.2 CPG [TQ7.2 CPG] *500 Å*
Tide Quencher™ 7.2 CPG [TQ7.2 CPG] *1000 Å*
Tide Quencher™ 7.2WS maleimide [TQ7.2WS maleimide]
Tide Quencher™ 7.2WS azide [TQ7.2WS azide]
Tide Quencher™ 7.2WS alkyne [TQ7.2WS alkyne]
Tide Quencher™ 8WS acid [TQ8WS acid]
Tide Quencher™ 8WS amine [TQ8WS amine]
Tide Quencher™ 8 CPG [TQ8 CPG] *500 Å*
Tide Quencher™ 8WS maleimide [TQ8WS maleimide]
Tide Quencher™ 8WS succinimidyl ester [TQ8WS SE]
Tide Quencher™ 8WS azide [TQ8WS azide]
Tide Quencher™ 8WS alkyne [TQ8WS alkyne]
Tide Quencher™ 8 CPG [TQ8 CPG] *1000 Å*
Tide Quencher™ 3WS maleimide [TQ3 maleimide]
Show More (82)

OverviewpdfSDSpdfProtocol


Molecular weight
1163.47
Tide Quencher™ 7.2WS (TQ7.2WS) is a non-fluorescent molecule designed to efficiently quench the fluorescence of common NIR fluorophores such as Cy7, Alexa Fluor® 700, Alexa Fluor® 750, iFluor® 700, iFluor® 710, iFluor® 720 and iFluor® 750. It is an improved version of TQ7 and BHQ3. TQ7.2WS is designed to be a superior quencher with (a). much stronger absorption, and (b). much higher quenching efficiency for NIR dyes. Tide Quencher™ 7.2WS succinimidyl ester is primarily used for the post-labeling of amino-modified oligonucleotides and the N-terminal or lysine residues of peptides. It can be used in techniques such as polymerase chain reaction (PCR), real-time PCR, and DNA sequencing. In these applications, fluorescence signals are used to monitor the amplification or detection of specific DNA sequences. TQ7.2WS quenches the fluorescent signal until a specific event (like DNA strand separation or primer extension) occurs, leading to an increase in fluorescence that can be detected and quantified. Fluorescence resonance energy transfer (FRET)-based assays are widely used to detect and measure the presence of specific molecules in a sample. They involve the use of a fluorescent molecule (fluorophore) and a quencher molecule such as TQ7.2WS. The fluorophore emits light when excited by a specific wavelength of light, while the quencher molecule absorbs this emitted light, effectively "quenching" the fluorescence signal.

Calculators


Common stock solution preparation

Table 1. Volume of DMSO needed to reconstitute specific mass of Tide Quencher™ 7.2WS succinimidyl ester [TQ7.2WS SE] to given concentration. Note that volume is only for preparing stock solution. Refer to sample experimental protocol for appropriate experimental/physiological buffers.

0.1 mg0.5 mg1 mg5 mg10 mg
1 mM85.95 µL429.749 µL859.498 µL4.297 mL8.595 mL
5 mM17.19 µL85.95 µL171.9 µL859.498 µL1.719 mL
10 mM8.595 µL42.975 µL85.95 µL429.749 µL859.498 µL

Molarity calculator

Enter any two values (mass, volume, concentration) to calculate the third.

Mass (Calculate)Molecular weightVolume (Calculate)Concentration (Calculate)Moles
/=x=

Images


References


View all 16 references: Citation Explorer
Noninvasive Imaging OX40+ Activated T Cells Provides Early Warning of Rheumatoid Arthritis.
Authors: Wen, Gang and Lei, Hongwei and Qi, Baochang and Duan, Shao and Xiao, Zunyu and Han, Chaozhe and Xia, Yifei and Jing, Chengwei and Liu, Jianyu and Li, Chao
Journal: Molecular imaging and biology (2023): 621-629
A stapled chromogranin A-derived peptide homes in on tumors that express αvβ6 or αvβ8 integrins.
Authors: Monieri, Matteo and Rainone, Paolo and Sacchi, Angelina and Gori, Alessandro and Gasparri, Anna Maria and Coliva, Angela and Citro, Antonio and Ferrara, Benedetta and Policardi, Martina and Valtorta, Silvia and Pocaterra, Arianna and Alfano, Massimo and Sheppard, Dean and Piemonti, Lorenzo and Moresco, Rosa Maria and Corti, Angelo and Curnis, Flavio
Journal: International journal of biological sciences (2023): 156-166
Phase 1/2a, open-label, multicenter study of RM-1929 photoimmunotherapy in patients with locoregional, recurrent head and neck squamous cell carcinoma.
Authors: Cognetti, David M and Johnson, Jennifer M and Curry, Joseph M and Kochuparambil, Samith T and McDonald, Darren and Mott, Frank and Fidler, Mary J and Stenson, Kerstin and Vasan, Nilesh R and Razaq, Mohammad A and Campana, John and Ha, Patrick and Mann, Grace and Ishida, Kosuke and Garcia-Guzman, Miguel and Biel, Merrill and Gillenwater, Ann M
Journal: Head & neck (2021): 3875-3887
Fluorescence Imaging of the Ureter in Minimally Invasive Pelvic Surgery.
Authors: Huh, Warner K and Johnson, John L and Elliott, Emily and Boone, Jonathan D and Leath, Charles A and Kovar, Joy L and Kim, Kenneth H
Journal: Journal of minimally invasive gynecology (2021): 332-341.e14
A phase I, single-center, open-label study of RM-1929 photoimmunotherapy in Japanese patients with recurrent head and neck squamous cell carcinoma.
Authors: Tahara, Makoto and Okano, Susumu and Enokida, Tomohiro and Ueda, Yuri and Fujisawa, Takao and Shinozaki, Takeshi and Tomioka, Toshifumi and Okano, Wataru and Biel, Merrill A and Ishida, Kosuke and Hayashi, Ryuichi
Journal: International journal of clinical oncology (2021): 1812-1821
Challenging a Preconception: Optoacoustic Spectrum Differs from the Optical Absorption Spectrum of Proteins and Dyes for Molecular Imaging.
Authors: Fuenzalida Werner, Juan Pablo and Huang, Yuanhui and Mishra, Kanuj and Janowski, Robert and Vetschera, Paul and Heichler, Christina and Chmyrov, Andriy and Neufert, Clemens and Niessing, Dierk and Ntziachristos, Vasilis and Stiel, Andre C
Journal: Analytical chemistry (2020)
Tumour-specific fluorescence-guided surgery for pancreatic cancer using panitumumab-IRDye800CW: a phase 1 single-centre, open-label, single-arm, dose-escalation study.
Authors: Lu, Guolan and van den Berg, Nynke S and Martin, Brock A and Nishio, Naoki and Hart, Zachary P and van Keulen, Stan and Fakurnejad, Shayan and Chirita, Stefania U and Raymundo, Roan C and Yi, Grace and Zhou, Quan and Fisher, George A and Rosenthal, Eben L and Poultsides, George A
Journal: The lancet. Gastroenterology & hepatology (2020): 753-764
Ultrabright fluorescent nanoscale labels for the femtomolar detection of analytes with standard bioassays.
Authors: Luan, Jingyi and Seth, Anushree and Gupta, Rohit and Wang, Zheyu and Rathi, Priya and Cao, Sisi and Gholami Derami, Hamed and Tang, Rui and Xu, Baogang and Achilefu, Samuel and Morrissey, Jeremiah J and Singamaneni, Srikanth
Journal: Nature biomedical engineering (2020): 518-530
Lateral flow immunoassay for 5-hydroxyflunixin based on near-infrared fluorescence molecule as an alternative label to gold nanoparticles.
Authors: Fan, Ruiqi and Zhang, Wanjun and Jin, Yongpeng and Zhao, Rongmao and Yang, Chunjiang and Chen, Qian and He, Lidong and Chen, Yiqiang
Journal: Mikrochimica acta (2020): 368
Evaluation of Targeting Efficiency of Joints with Anticollagen II Antibodies.
Authors: Lofchy, Laren A and Vu, Vivian P and Banda, Nirmal K and Ramirez, Joseline Ramos and Smith, Weston J and Gifford, Geoffrey and Gaikwad, Hanmant and Scheinman, Robert I and Simberg, Dmitri
Journal: Molecular pharmaceutics (2019): 2445-2451